Part Number | AP8459WW |
---|---|
UPC | 731304317586 |
UPC11 | 73130431758 |
EAN | 0731304317586 |
Prop 65 | This product can expose you to chemicals including: Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Depth | 2.01 inch |
Height | 72.01 inch |
Width | 2.20 inch |
Weight | 13.40 pound |
Presentation | APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency. |
---|---|
Lead Time | Usually in Stock |
Provided Equipment | CAN Port Terminator Installation guide Rack Mounting brackets Safety guide Serial configuration cable |
Colour | Black |
Depth | 2.01 in (5.1 cm) |
Height | 72.01 in (182.9 cm) |
Product Weight | 13.40 lb(US) (6.08 kg) |
Width | 2.20 in (5.6 cm) |
In Rated Current | 16 A |
Permissible Voltage | 100…240 V |
Input Current Limits | 20 A |
Load Capacity | 3300 VA |
Network Frequency | 50/60 Hz |
Plug Standard | IEC 60320 C20 |
Input Voltage | 200 V 208 V 230 V |
Number Of Power Socket Outlets | 21 IEC 60320 C13 3 IEC 60320 C19 |
Product Certifications | PSE UL Listed VCCI Class A VDE |
Standards | EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3 FCC Part 15 class A ICES-003 |
Ambient Air Temp For Op | 23…113 °F (-5…45 °C) |
Relative Humidity | 5…95 % |
Operating Altitude | 0...10000 ft |
Ambient Air Temp For Storage | -13…149 °F (-25…65 °C) |
Storage Altitude | 0…50000 ft (0.00…15240.00 m) |
GTIN | 00731304317586 |
EU RoHs Directive | Compliant |
Lead Free | Yes |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Halogen Content Performance | Halogen free product |
Warranty | 2 years repair or replace |