Part Number | XPSMF3022 |
---|---|
UPC | 389119010627 |
UPC11 | 38911901062 |
EAN | 3389119010627 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Return Indicator | No |
Depth | 2.62 inch |
Height | 4.45 inch |
Width | 9.96 inch |
Weight | 2.65 pound |
Range Of Product | Preventa Safety automation |
---|---|
Product Or Component Type | Preventa safety PLC compact |
Safety Module Name | XPSMF30 |
Safety Module Application | For numerous machine safety functions and for the protection of personnel |
Safety Use Category | Category 4 EN 954-1/ISO 13849-1 SIL 3 IEC 61508 |
Structure Type | 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet |
Function Of Module | Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output |
Us Rated Supply Voltage | 24 V DC - 15...20 % |
No Load Current | 0.5 A |
Protection Type | Internal fuse |
Clock | With, supplied by backup capacitor for 1 week following loss of supply |
Response Time | Depending on size of application |
Memory Description | User logic 250 kB application User logic 250 kB data |
Discrete Input Number | 20 not isolated |
Voltage State 0 Guaranteed | <= 5 V discrete input |
Voltage State 1 Guaranteed | >= 15 V discrete input |
Current State 0 Guaranteed | 1.25...1.5 mA discrete input) |
Current State 1 Guaranteed | >= 2 mA discrete input) |
Discrete Input Voltage | 20 V |
Discrete Input Current | 100 mA |
Input Protection Type | Protected against short-circuit to earth Protected against short-circuit |
Input Overvoltage Protection | 500 V discrete input IEC 61000-4-5 |
Switching Voltage | 7.5 V |
Discrete Output Number | 8 |
Discrete Output Voltage | 24 V DC |
Output Voltage Tolerance | +/- 2% |
Discrete Output Current | 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 mA all channels) |
Minimum Load | 2 mA per discrete output |
Leakage Current | 1 mA 2 V at state 0 discrete output |
Overload Protection | Shutdown of outputs concerned with cyclic reconnection |
Communication Port Protocol | Modbus TCP/IP 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Safe Ethernet 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
Exchange Mode | Half duplex, full duplex, autonegotiation Modbus TCP/IP Half duplex, full duplex, autonegotiation safe Ethernet |
Method Of Access | Slave Modbus TCP/IP |
Concept | Transparent Ready, Modbus TCP/IP |
Web Server | Class A10, Modbus TCP/IP |
Web Services | Modbus identification request, Modbus TCP/IP Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP Modbus TCP/IP server, Modbus TCP/IP Standard 502, Modbus TCP/IP |
Operating Distance | <= 100 m between station) discrete input <= 100 m between station) discrete output |
Number Of Terminal Blocks | 1 power supply 2 discrete output 5 discrete input |
Connections - Terminals | Discrete input/output circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible with cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible without cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.25...2 x 1 mm² AWG 22...AWG 18) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² AWG 22...AWG 16) flexible with cable end |
Tightening Torque | 1.95…2.21 lbf.in (0.22…0.25 N.m) |
Wire Stripping Length | 0.35 in (9 mm) |
Current Consumption | 8 A 24 V DC on power supply |
Mounting Support | 35 mm symmetrical DIN rail |
Depth | 2.62 in (66.5 mm) |
Height | 4.45 in (113 mm) |
Width | 9.96 in (253 mm) |
Product Weight | 2.65 lb(US) (1.2 kg) |
Standards | DIN V 19250 DIN V 0801 EN 50156 pending IEC 61131 |
Immunity To Microbreaks | 10 ms |
IP Degree Of Protection | IP20 enclosure) |