Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Preventa Safety automation- Preventa safety PLC compact – Modbus serial protocol
XPSMF3522
Preventa Safety automation- Preventa safety PLC compact – Modbus serial protocol
Specifications
Part Number XPSMF3522
UPC 389119010603
UPC11 38911901060
EAN 3389119010603
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Return Indicator No
Depth 2.62 inch
Height 4.45 inch
Width 9.96 inch
Weight 2.65 pound
Characteristics
Range Of Product Preventa Safety automation
Product Or Component Type Preventa safety PLC compact
Safety Module Name XPSMF35
Safety Module Application For numerous machine safety functions and for the protection of personnel
Safety Use Category Category 4 EN 954-1/ISO 13849-1 SIL 3 IEC 61508
Structure Type 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet
Function Of Module Closed circuit scanning of input channels analogue input circuit Measuring 0 to 20 mA currents using shunt analogue input circuit Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Single-pole measuring of 0 to 10 V voltages analogue input circuit
Us Rated Supply Voltage 24 V DC - 15...20 %
No Load Current 0.75 A
Protection Type Internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory Description User logic 250 kB application User logic 250 kB data
Discrete Input Number 24 not isolated
Voltage State 0 Guaranteed <= 5 V discrete input
Voltage State 1 Guaranteed 24...30 V discrete input
Current State 0 Guaranteed 1...1.5 mA discrete input)
Current State 1 Guaranteed 3.5...4.5 mA discrete input)
Discrete Input Voltage 20 V
Discrete Input Current 100 mA
Input Protection Type Protected against short-circuit to earth Protected against short-circuit
Input Overvoltage Protection 500 V discrete input IEC 61000-4-5 -4…15 V analogue input circuit
Discrete Output Number 8
Discrete Output Voltage 24 V DC
Output Voltage Tolerance +/- 2%
Discrete Output Current 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 mA all channels)
Minimum Load 2 mA per discrete output
Leakage Current 1 mA 2 V at state 0 discrete output
Overload Protection Shutdown of outputs concerned with cyclic reconnection
Analogue Input Number 8
Analogue Output Type Not isolated
External Resistance 250 Ohm analogue input circuit 500 Ohm analogue input circuit
Analogue Input Range 0...20 mA 500 Ohm 0...10 V
Input Voltage Limits 0.1...11.5 V analogue input circuit
Input Current Limits 0.4…23 mA 500 Ohm analogue input circuit
Analogue Input Resolution 12 bits
Safety Accuracy +/- 2 % analogue input circuit
Internal Input Resistance 500 MOhm for signal source analogue input circuit 1 kOhm analogue input circuit 3.7 Ohm counting inputs
Counting Input Number 2
Counting Input Type Non isolated
Counting Frequency 100 kHz
Operating Threshold 0...0.05 V, 5 V low counting inputs 13...33 V, 24 V high counting inputs -3...5 V, 24 V low counting inputs 4...6 V, 5 V high counting inputs
Counter Inputs Resolution 24 bits
Dv/Dt 1 V/µs counting inputs
Communication Port Protocol Modbus TCP/IP 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Safe Ethernet 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Modbus RTU 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Exchange Mode Half duplex, full duplex, autonegotiation Modbus TCP/IP Half duplex, full duplex, autonegotiation safe Ethernet
Method Of Access Slave Modbus Slave Modbus TCP/IP Slave Profibus
Number Of Addresses 122 Modbus
Concept Transparent Ready, Modbus TCP/IP
Web Server Class A10, Modbus TCP/IP