Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Preventa module Cat.4 features 2*XPSUAF + enabling movement 48-240vac/dc screw
XPSUS32AP
Preventa module Cat.4 features 2*XPSUAF + enabling movement 48-240vac/dc screw

This product is part of the Preventa XPS Universal safety relays. This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain, Two hand control station or Enabling switch. The safety relay is powered with 48-240V AC/DC, and equipped with a screw removable terminal block. XPS Universal safety relay can forward more than 40 different messages between the solid state output of the relay and a standard digital input of a PLC, reducing the down time of the machine, precising the root cause of production stop. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 2 NO safety outputs, and 1 solid-state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PL e/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging, Mainly designed for a broad range of machines of the general mechanical engineering. This safety relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061, IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061 standards, and certified by cULus and TUV. This relay is mounted on a 35mm symmetrical DIN rail. Preventa XPS Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity.

Add to Quote Catalogue
Specifications
Part Number XPSUS32AP
EAN 3606489601836
Availability N
Lead Time 16
HTs Code 8536490055
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule SAF2
Depth 4.72 inch
Height 3.94 inch
Width 0.89 inch
Weight 0.44 pound
Characteristics
Range Of Product Preventa Safety automation
Product Or Component Type Preventa safety module
Safety Module Name XPSUS
Safety Module Application For electrical monitoring of two-hand control stations Monitoring antivalent contacts For emergency stop, guard and light curtain monitoring For enabling switch monitoring
Function Of Module Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Monitoring 2 PNP sensors Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Enabling switch monitoring Proximity sensor monitoring Monitoring two-hand control station
Safety Level Can reach PL e/category 4 ISO 13849-1 Can reach SILCL 3 IEC 62061 Can reach SIL 3 IEC 61508
Safety Reliability Data MTTFd > 30 years ISO 13849-1 Dcavg >= 99 % ISO 13849-1 PFHd = 1.61E-09 ISO 13849-1 HFT = 1 IEC 62061 PFHd = 1.61E-09 IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 1.61E-09 IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1
Electrical Circuit Type NC pair PNP pair Antivalent pair OSSD pair
Connections - Terminals Removable screw terminal block, 0.2...2.5 mm² solid or flexible Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Us Rated Supply Voltage 48...240 V AC/DC - 10...10 %
Synchro Time Between Inputs 0.5 s 2 s 4 s
Type Of Start Automatic/manual/monitored
Power Consumption In W 3 W 48 V DC
Power Consumption In Va 8.5 VA 240 V AC 50/60 Hz
Input Protection Type Internal, electronic
Safety Outputs 2 NO
Safety Inputs 2
Maximum Wire Resistance 500 Ohm
Input Compatibility Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 Two-hand control EN 574/ISO 13851-III A 3-wire proximity sensors PNP
Output Type relay output, 250 V AC relay output, 250 V AC relay output, 24 V DC relay output, 24 V DC
Ie Rated Operational Current 5 A AC-1 3 A AC-15 5 A DC-1 3 A DC-13 3 A AC-1 1 A AC-15 3 A DC-1 1 A DC-13
Control Outputs 3 pulsed output
Input/Output Type Semiconductor pulsed diagnostic output Z1, 20 mA
Ith Cnvtl Free Air Therm Crrt 8 A
Associated Fuse Rating 10 A gG NO relay output circuit IEC 60947-1
Minimum Output Current 10 mA relay output
Minimum Output Voltage 12 V relay output
Response Time On Input Open 20 ms
Ui Rated Insulation Voltage 250 V 2)EN/IEC 60947-1
Uimp Rated Imp Wstd Voltage 4 kV II EN/IEC 60947-1
Local Signalling Power ON LED green) Error LED red) Safety output status LED yellow) Start input LED yellow) Safety input S12 LED yellow) Safety input S13 LED yellow) Safety input S22 LED yellow) Safety input S23 LED yellow)
Mounting Support 35 mm symmetrical DIN rail
Depth 4.72 in (120 mm)
Height 3.94 in (100 mm)
Width 0.89 in (22.5 mm)
Product Weight 0.44 lb(US) (0.200 kg)
Standards IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard
Product Certifications TÜV CULus
IP Degree Of Protection IP20 terminals)EN/IEC 60529 IP40 housing)EN/IEC 60529 IP54 mounting area)EN/IEC 60529
Ambient Air Temp For Storage -13…185 °F (-25…85 °C)
Relative Humidity 5…95 % non-condensing
Nbr. Of Units In Pkg. 1
Green Premium Status Green Premium product
EU RoHs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury Free Yes