| Part Number | XPSMFDO801 |
|---|---|
| UPC | 389119010795 |
| UPC11 | 38911901079 |
| EAN | 3389119010795 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Return Indicator | No |
| Weight | 1.32 pound |
| Range Of Product | Preventa Safety automation |
|---|---|
| Product Or Component Type | Relay output card |
| Safety Module Name | XPS MF60 |
| Safety Use Category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function Of Module | Monitoring safety dialogue Monitoring safety actuators |
| Standards | EN 50156 pending DIN V 0801 IEC 61131 DIN V 19250 |
| Us Rated Supply Voltage | 24 V DC - 15...20 % |
| Number Of Outputs | 8 relay |
| Connections - Terminals | removable screw terminal block, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end removable screw terminal block, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end removable screw terminal block, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end removable screw terminal block, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end removable screw terminal block, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end removable screw terminal block, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end removable screw terminal block, 2 x 0.5 mm² AWG 20) flexible with cable end removable screw terminal block, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end |
| Marking | CE |
| Output Type | Relay, 2 NO per output, volt-free |
| Contacts Material | Silver alloy, gold flashed |
| Switching Time | 30 ms |
| Reset Time | 20 ms |
| Contact Bounce Time | 30 ms |
| Electrical Durability | 250000 cycles |
| Mechanical Durability | 10000000 cycles |
| Minimum Switching Voltage | 6 V AC |
| Maximum Switching Voltage | 250 V AC |
| Switching Current Capacity | 3.15 A / 100 A with internal fuse |
| Switching Capacity In Va | <700 VA 1 |
| Switching Capacity In W | <95 30 V with suitable external fuse) <33 110 V <40 70 V |
| Current Consumption | 0.2 A 3.3 V DC rack 0.7 A 24 V DC power supply |
| Product Weight | 1.32 lb(US) (0.6 kg) |
| Product Certifications | TÜV UL CSA C-tick |
| IP Degree Of Protection | IP20 with covering plate on unused in rack I/O card slots) |
| Ambient Air Temp For Op | 32…140 °F (0…60 °C) EN/IEC 61131-2 |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) EN/IEC 61131-2 |
| Relative Humidity | 95 % supply not connected |
| Operating Altitude | < 6561.68 ft (2000 m) |
| Pollution Degree | 2 |
| Electrical Shock Protect Class | Class II IEC 61131-2 |
| Electromagnetic Compatibility | EN/IEC 61131-2 |
| Vibration Resistance | 1 gn 10…150 Hz) - 10 cycles per axis - EN 61131-2 |
| Shock Resistance | 15 gn 11 ms 2 cycles per axis)EN 61131-2 |
| Resist Electrostatic Dischrg | 4 kV contact EN/IEC 61000-4-2 8 kV on air EN/IEC 61000-4-2 |
| Resist To Electromagn Fields | 9.14 V/m (10 V/m) 26…1000 MHz), amplitude modulation 80 % EN/IEC 61000-4-3 |
| Category | 22478 - XPS SAFETY PLC |
| Discount Schedule | SAF1 |
| GTIN | 03389119010795 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | DE |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Warranty | 18 months |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366