| Part Number | XMLA500E2S11 |
|---|---|
| Country of Origin | CZ |
| UPC | 389110712438 |
| UPC11 | 38911071243 |
| EAN | 3389110712438 |
| Availability | N |
| Lead Time | 21 |
| UNSPSC | 39122210 |
| ECCN | EAR99 |
| HTs Code | 9032200000 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | DS2 |
| Return Indicator | No |
| Depth | 2.95 inch |
| Height | 4.45 inch |
| Width | 1.38 inch |
| Weight | 1.65 pound |
| Range Of Product | OsiSense XM |
|---|---|
| Product Or Component Type | Electromechanical pressure sensor |
| Pressure Sensor Type | Electromechanical pressure sensor |
| Device Short Name | XMLA |
| Pressure Sensor Size | 7251.89 psi (500 bar) |
| Controlled Fluid | Fresh water 32…320 °F (0…160 °C)) |
| Fluid Connection Type | G 1/4 (female) ISO 228 |
| Electrical Connection | Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm² 1 connector Pg 13 |
| Awg Gauge | AWG 20...AWG 14 |
| Cable Entry | Cable gland 0.35…0.51 in (9…13 mm) |
| Contacts Type And Composition | 1 C/O |
| Pressure Swt Type Of Operation | Detection of 1 single threshold |
| Electrical Circuit Type | Control circuit |
| Type Of Scale | Fixed differential |
| Local Display | With |
| Adj Range High Setting | 435.11…7251.89 psi (30…500 bar) |
| Adj Range Low Setting | 145.04…6599.22 psi (10…455 bar) |
| Max Perm Accidental Pressure | 16316.75 psi (1125 bar) |
| Destruction Pressure | 32633.49 psi (2250 bar) |
| Pressure Actuator | Piston |
| Materials In Contact Wth Fluid | PTFE Brass Stainless steel FPM, FKM |
| Enclosure Material | Zinc alloy |
| In Rated Current | 3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1 |
| Natural Diff At Low Setting | 290.08 psi (20 bar) +/- 6 bar) |
| Natural Diff At High Setting | 652.67 psi (45 bar) +/- 10 bar) |
| Max Perm Pressure - Per Cycle | 9064.86 psi (625 bar) |
| Terminal Block Type | 4 terminals |
| Operating Rate | 60 cyc/mn |
| Repeat Accuracy | 2 % |
| Ui Rated Insulation Voltage | 300 V UL 508 500 V EN/IEC 60947-1 300 V CSA C22.2 No 14 |
| Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-1 |
| Auxiliary Contacts Operation | Snap action |
| Contacts Material | Silver contacts |
| Resistance Across Terminals | 25 mOhm IEC 255-7 category 3 25 mOhm NF C 93-050 method A |
| Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
| Mechanical Durability | 3000000 cycles |
| Setting | External |
| Height | 4.45 in (113 mm) |
| Depth | 2.95 in (75 mm) |
| Width | 1.38 in (35 mm) |
| Product Weight | 1.65 lb(US) (0.75 kg) |
| Standards | CE UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 |
| Product Certifications | LROS (Lloyds register of shipping) BV CCC EAC UL CSA |
| Protective Treatment | TC standard version |
| Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Operating Position | Any position |
| Vibration Resistance | 4 gn 30…500 Hz)IEC 60068-2-6 |
| Shock Resistance | 50 gn IEC 60068-2-27 |
| Electrical Shock Protect Class | Class I IEC 1140 Class I IEC 536 Class I NF C 20-030 |