Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Pressure sensors XMLR 400bar – G 1/4 – 24VDC – 4..20 mA – PNP – M12
XMLR400M1P25
Pressure sensors XMLR 400bar – G 1/4 – 24VDC – 4..20 mA – PNP – M12

This sensor is part of the XMLR range, an offer of electronic pressure sensors with a 4-digit display, for configuration functions and for fast diagnostic. The XMLR pressure sensors are designed for the the pressure control of a large number of fluids. This product has a pressure range of 0bar to 400bar, with a maximum permissible accidental pressure at 1200bar and a destruction pressure at 2400bar. Made of 316L stainless steel, this pressure sensor is compact and robust. It has one analogue output (4mA to 20mA and one solid-state output (PNP type). It is appropriate for controlling fresh water, air, hydraulic oil and refrigeration fluid. This pressure sensor features a compact plastic body, a G 1/4 DIN 3852-Y (female) 316L stainless steel fluid connector and a M12 electrical connector. It is suitable for moulding and thermoforming presses, injection machines, pneumatic systems and assembly machinery, hydraulic systems of lifting and handling equipment, pumping and fresh water treatment. It complies with CE, EAC, CULus certifications, and with EN/IEC 61326-2-3 and UL 61010-1 standards. Dedicated accessories, to be ordered separatly, are available to facilitate the setting of the pressure sensor. Cooler with G 1/4 A connections, fixing bracket, pre-wired connectors, jumper cables, etc. The body of the OsiSense XMLR pressure sensor can be turned through 300°, thus enabling the front face of the product to be orientated as required following connection to the pressure inlet pipe. The stainless steel 316L fluid entry and fibreglass impregnated polyacrylamide body provide the XMLR pressure sensors with excellent mechanical resistance, improved corrosion resistance and an P65/IP67 degree of protection.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XMLR400M1P25
Country of Origin CH
UPC 389119611824
UPC11 38911961182
EAN 3389119611824
Availability N
Lead Time 26
ECCN EAR99
HTs Code 9032200000
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule DS2
Return Indicator No
Depth 1.65 inch
Height 3.46 inch
Width 1.61 inch
Weight 0.41 pound
Characteristics
Range Of Product OsiSense XM
Product Or Component Type Electronic pressure sensors
Pressure Sensor Type Pressure transmitter
Pressure Swt Type Of Operation Pressure transmitter with 1 switching output
Device Short Name XMLR
Pressure Sensor Size 5801.51 psi (400 bar) 5800 psi (39989.59 kPa)
Max Perm Accidental Pressure 17404.53 psi (1200 bar) 17400 psi (119968.77 kPa) 120 MPa
Destruction Pressure 240 MPa 34809.06 psi (2400 bar) 34800 psi (239937.54 kPa)
Controlled Fluid Fresh water 32…176 °F (0…80 °C)) Air -4…176 °F (-20…80 °C)) Hydraulic oil -4…176 °F (-20…80 °C)) Refrigeration fluid -4…176 °F (-20…80 °C))
Fluid Connection Type G 1/4 (female) DIN 3852-Y
[Us] Rated Supply Voltage 24 V DC SELV 17…33 V)
Current Consumption <= 50 mA
Electrical Connection Male connector M12, 4 pins
Analogue Output Function 4...20 mA
Type Of Output Signal Analogue + discrete
Discrete Output Type Solid state PNP, NO/NC programmable
Maximum Switching Current 250 mA
Contacts Type And Composition NO/NC programmable
Type Of Scale Fixed differential
Voltage Drop 2 V
Adj Range High Setting 464…5800 psi (3199.17…39989.59 kPa) 464.12…5801.51 psi (32…400 bar) 3.2…40 MPa
Adj Range Low Setting 290…5626 psi (1999.48…38789.90 kPa) 290.08…5627.46 psi (20…388 bar) 2…38.8 MPa
Minimum Differential Travel 174.05 psi (12 bar) 1.2 MPa 174 psi (1199.69 kPa)
Materials In Contact Wth Fluid 316L stainless steel
Front Material Polyester
Housing Material 316L stainless steel Polyacrylamide
Operating Position Any position, but disposals can falsified the measurement in case of upside down mounting
Protection Type Reverse polarity Short-circuit protection Overload protection Overvoltage protection
Response Time On Output <= 10 ms analog output <= 5 ms discrete output
Switching Output Time Delay 0...50 s in steps of 1 second
Display Type 4 digits 7 segments
Local Signalling Light ON when switch is actuated 1 LED yellow)
Display Response Time Type Fast 50 ms Normal 200 ms Slow 600 ms
Delay First Up 300 ms
Overall Accuracy <= 1 % of the measuring range
Linearity Error On Analogue Output <= 0.5 % of the measuring range
Hysteresis On Analogue Output <= 0.2 % of the measuring range
Measurement Accuracy On Switching Output <= 0.6 % of the measuring range
Repeat Accuracy <= 0.2 % of the measuring range
Drift Of The Sensitivity +/- 0.03 % of measuring range/°C
Drift Of The Zero Point +/- 0.1 % of measuring range/°C
Display Accuracy <= 1 % of the measuring range
Mechanical Durability 10000000 cycles
Depth 1.65 in (42 mm)
Height 3.46 in (88 mm)
Width 1.61 in (41 mm)
Product Weight 0.41 lb(US) (0.186 kg)
Uimp Rated Imp Wstd Voltage 0.5 kV DC
Electromagnetic Compatibility Susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 Immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 Surge immunity test 1 kV EN/IEC 61000-4-5 Electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 Electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
Marking CE
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews