Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Pressure sensors XMLR 25bar – 1/4″ 18 NPT – 24VDC – 4..20 mA – M12
XMLR025G0T26
Pressure sensors XMLR 25bar – 1/4″ 18 NPT – 24VDC – 4..20 mA – M12
Specifications
Part Number XMLR025G0T26
Country of Origin CH
UPC 785901288190
UPC11 78590128819
EAN 3389119610988
Availability N
Lead Time 26
UNSPSC 39122210
ECCN EAR99
HTs Code 9026208000
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule DS2
Return Indicator No
Depth 1.65 inch
Height 3.94 inch
Width 1.61 inch
Weight 0.47 pound
Characteristics
Range Of Product OsiSense XM
Product Or Component Type Electronic pressure sensors
Pressure Sensor Type Pressure transmitter
Pressure Swt Type Of Operation Pressure transmitter
Device Short Name XMLR
Pressure Sensor Size 362 psi (2495.90 kPa) 362.59 psi (25 bar)
Max Perm Accidental Pressure 1450 psi (9997.40 kPa) 1450.38 psi (100 bar) 10 MPa
Destruction Pressure 10 MPa 1450 psi (9997.40 kPa) 1450.38 psi (100 bar)
Controlled Fluid Fresh water 32…176 °F (0…80 °C)) Air -4…176 °F (-20…80 °C)) Hydraulic oil -4…176 °F (-20…80 °C)) Refrigeration fluid -4…176 °F (-20…80 °C))
Fluid Connection Type 1/4" - 18 NPT (female)
[Us] Rated Supply Voltage 24 V DC SELV 17…33 V)
Current Consumption <= 50 mA
Electrical Connection Male connector M12, 4 pins
Analogue Output Function 4...20 mA
Type Of Output Signal Analogue
Type Of Scale Fixed differential
Materials In Contact Wth Fluid 316L stainless steel Fluorocarbon FKM (Viton) Ceramic
Front Material Polyester
Housing Material Polyacrylamide 316L stainless steel
Operating Position Any position, but disposals can falsified the measurement in case of upside down mounting
Protection Type Overload protection Overvoltage protection Reverse polarity Short-circuit protection
Response Time On Output <= 10 ms analog output
Display Type 4 digits 7 segments
Display Response Time Type Fast 50 ms Normal 200 ms Slow 600 ms
Delay First Up 300 ms
Overall Accuracy <= 1 % of the measuring range
Linearity Error On Analogue Output <= 0.5 % of the measuring range
Hysteresis On Analogue Output <= 0.2 % of the measuring range
Measurement Accuracy On Switching Output <= 0.6 % of the measuring range
Repeat Accuracy <= 0.2 % of the measuring range
Drift Of The Sensitivity +/- 0.03 % of measuring range/°C
Drift Of The Zero Point +/- 0.1 % of measuring range/°C
Display Accuracy <= 1 % of the measuring range
Mechanical Durability 10000000 cycles
Depth 1.65 in (42 mm)
Height 3.94 in (100 mm)
Width 1.61 in (41 mm)
Product Weight 0.47 lb(US) (0.212 kg)
Uimp Rated Imp Wstd Voltage 0.5 kV DC
Electromagnetic Compatibility Susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 Immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 Surge immunity test 1 kV EN/IEC 61000-4-5 Electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 Electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
Marking CE
Product Certifications EAC CULus
Standards EN/IEC 61326-2-3 UL 61010-1
Ambient Air Temp For Op -4…176 °F (-20…80 °C)
Ambient Air Temp For Storage -40…176 °F (-40…80 °C)
IP Degree Of Protection IP65 EN/IEC 60529 IP67 EN/IEC 60529
Vibration Resistance 20 gn 10…2000 Hz)EN/IEC 60068-2-6
Shock Resistance 50 gn EN/IEC 60068-2-27
Category 21551 - XMLE,XMLF,XMLG PRESSURE SENSORS
Discount Schedule DS2
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews