Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Pressure sensor XMLA 10 bar – fixed scale 1 threshold – 1 C/O – with display
XMLA010P2S13
Pressure sensor XMLA 10 bar – fixed scale 1 threshold – 1 C/O – with display
Specifications
Part Number XMLA010P2S13
Depth 2.99 inch
Height 5.12 inch
Width 1.97 inch
Weight 1.51 pound
Characteristics
Range Of Product OsiSense XM
Product Or Component Type Electromechanical pressure sensor
Pressure Sensor Type Electromechanical pressure sensor
Device Short Name XMLA
Pressure Sensor Size 145.04 psi (10 bar)
Controlled Fluid Viscous product 32…320 °F (0…160 °C))
Fluid Connection Type 1/4" - 18 NPTF (female)
Electrical Connection Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Awg Gauge AWG 20...AWG 14
Cable Entry Cable gland 0.28…0.51 in (7…13 mm)
Contacts Type And Composition 1 C/O
Pressure Swt Type Of Operation Detection of 1 single threshold
Electrical Circuit Type Control circuit
Type Of Scale Fixed differential
Local Display With
Adj Range High Setting 8.70…145.04 psi (0.6…10 bar)
Adj Range Low Setting 1.45…137.79 psi (0.1…9.5 bar)
Max Perm Accidental Pressure 326.33 psi (22.5 bar)
Destruction Pressure 652.67 psi (45 bar)
Pressure Actuator Diaphragm
Materials In Contact Wth Fluid Steel FPM, FKM
Enclosure Material Zinc alloy
In Rated Current 3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
Natural Diff At Low Setting 7.25 psi (0.5 bar) +/- 0.05 bar)
Natural Diff At High Setting 7.25 psi (0.5 bar) +/- 0.05 bar)
Max Perm Pressure - Per Cycle 181.30 psi (12.5 bar)
Terminal Block Type 4 terminals
Operating Rate 120 cyc/mn
Repeat Accuracy 2 %
Ui Rated Insulation Voltage 300 V UL 508 500 V EN/IEC 60947-1 300 V CSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-1
Auxiliary Contacts Operation Snap action
Contacts Material Silver contacts
Resistance Across Terminals 25 mOhm IEC 255-7 category 3 25 mOhm NF C 93-050 method A
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Mechanical Durability 5000000 cycles
Setting External
Height 5.12 in (130 mm)
Depth 2.99 in (76 mm)
Width 1.97 in (50 mm)
Product Weight 1.51 lb(US) (0.685 kg)
Standards UL 508 CE EN/IEC 60947-5-1 CSA C22.2 No 14
Product Certifications EAC CCC LROS (Lloyds register of shipping) UL BV CSA
Protective Treatment TC standard version
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Operating Position Any position
Vibration Resistance 4 gn 30…500 Hz)IEC 60068-2-6
Shock Resistance 50 gn IEC 60068-2-27
Electrical Shock Protect Class Class I IEC 1140 Class I IEC 536 Class I NF C 20-030
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews