PowerPact multistandard – H-Frame – 60 A – 100 KA – Therm-Mag trip unit
NHJF36060TW
PowerPact multistandard – H-Frame – 60 A – 100 KA – Therm-Mag trip unit
Specifications
Part Number NHJF36060TW
Country of Origin US
UPC 785901622208
UPC11 78590162220
EAN 0785901622208
Availability N
UNSPSC 39121601
ECCN EAR99
HTs Code 8536200020
Prop 65 This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule DE2
Return Indicator No
Depth 3.39 inch
Height 6.42 inch
Width 4.09 inch
Weight 4.85 pound
Characteristics
Range Of Product PowerPact multistandard
Range PowerPact
Product Name H-Frame
Device Short Name H-Frame
Product Or Component Type Circuit breaker
Device Application Distribution
Poles Description 3P
Control Type Toggle
Mounting Mode Unit mount
Mounting Support DIN rail Backplate Flush
Electrical Connection Terminal nut line side Terminal nut load side
In Rated Current 60 A 104 °F (40 °C)
Ui Rated Insulation Voltage 750 V AC 50/60 Hz IEC 60947-2
Uimp Rated Imp Wstd Voltage 8 kV IEC 60947-2
Ue Rated Operational Voltage 525 V AC 50/60 Hz IEC 60947-2 690 V AC 50/60 Hz IEC 947-2 600 V AC 50/60 Hz UL 489
Rating Code HJ
Suitability For ISOlation Yes
Utilisation Category Category A
Mechanical Durability 4000 cycles
Electrical Durability 4000 cycles
Connection Pitch 1.77 in (45 mm)
Local Signalling ON/OFF indication
Contact Position Indicator Yes
Trip Unit Name TM
Trip Unit Technology Thermal-magnetic
Trip Unit Protection Functions Basic protection
Trip Unit Rating 60 A
Display Type 3 LEDs
Breaking Capacity Icu 100 kA 220/240 V - AC IEC 947-2 Icu 65 kA 380/415 V - AC IEC 947-2 Icu 65 kA 440/480 V - AC IEC 947-2 Icu 25 kA 500/525 V - AC IEC 947-2 100 kA 240 V - AC UL 489 65 kA 480 V - AC UL 489 25 kA 600 V - AC UL 489
Ics Rated Service Breaking Cap Ics 100 kA 220/240 V - AC IEC 947-2 Ics 65 kA 380/415 V - AC IEC 947-2 Ics 65 kA 440/480 V - AC IEC 947-2 Ics 25 kA 500/525 V - AC IEC 947-2
Lg Time Pick Up Adj Type Ir Fixed
Long Time Pick-Up Adjust Rng 1 In
Sh Time Pick-Up Adj Type Isd Fixed
Isd Short-Time Pick-Up Adj 1450 A
Overvoltage Category II
Provision For Padlocking Non padlockable
Height 6.42 in (163 mm)
Width 4.09 in (104 mm)
Depth 3.39 in (86 mm)
Standards NMX J-266 UL 489 IEC 60947-2 CSA C22.2 No 5 W-C-375B/GEN NEMA AB1
Product Certifications CE CCC
Product Weight 4.85 lb(US) (2.2 kg)
Tightening Torque 44.25 lbf.in (5 N.m) 0.00…0.15 in² (2.5…95 mm²) AWG 14...AWG 3/0)
IP Degree Of Protection IP40 IEC 60529
IK Degree Of Protection IK07 IEC 62262
Pollution Degree 3 IEC 60947-1 3 IEC 60664-1
Ambient Air Temp For Op 104 °F (40 °C)
Ambient Air Temp For Storage -58…185 °F (-50…85 °C)
Category 01115 - HG,HJ,JG,JJ UNIT MT BREAKER/SWITCH