The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs of 1 A, 5 A; current class 2, 10, 20 A; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting or panel mounting (with back to back adapter) transducer, plus 2 display options, further enhance the flexibility and adaptability of the ION9000.
Add to Quote CataloguePart Number | METSEION92030 |
---|---|
Country of Origin | MX |
UPC | 606481352309 |
UPC11 | 60648135230 |
EAN | 3606481352309 |
Availability | N |
Lead Time | 80 |
UNSPSC | 83101808 |
ECCN | EAR99 |
HTs Code | 9028300000 |
Prop 65 | This product can expose you to chemicals including: Dichloromethane (Methylene chloride) and Bisphenol A (BPA) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | PM1 |
Return Indicator | No |
Depth | 5.33 inch |
Height | 6.30 inch |
Width | 6.30 inch |
Weight | 3.31 pound |
Range | PowerLogic |
---|---|
Device Short Name | ION92030 |
Product Or Component Type | Energy and power quality meter |
Device Application | Power monitoring WAGES metering Net metering Medium voltage High voltage |
Metering Type | Demand current I1, I2, I3, I4, I5 Peak demand currents Demand power P, Q, S Peak demand power PM, QM, SM Calculated active and reactive energy (+/- W.h, +/- VAR.h) |
Power Quality Analysis | EN 50160 compliance checking IEEE 519 harmonic limit IEC 61000-4-30 class A compliance reporting IEEE 519 compliance reporting waveform capture total demand distortion total harmonic distortion up to the 63rd harmonic up to the 127th harmonic with software disturbance direction detection dip, swell and transient half cycle data acquisition transient detection (20 µs) |
Type Of Measurement | Voltage sags and swells Current sags and swells Voltage Current Frequency Active and reactive power total Apparent power total Active and reactive power per phase Apparent power per phase Power factor total Power factor per phase Active and reactive energy Apparent energy Harmonic distorsion (I THD & U THD) |
Us Rated Supply Voltage | 90...480 V AC 45...66 Hz +/- 10 % 90...120 V AC 400 Hz +/- 10 % 110...480 V DC +/- 15 % |
Network Frequency | 50 Hz 60 Hz |
Ride-Through Time | 100 ms 6 cycles at 60 Hz 120 V AC typical 400 ms 24 cycles at 60 Hz 240 V AC typical 1200 ms 72 cycles at 60 Hz 480 V AC typical |
In Rated Current | 1 A 5 A 20 A |
Type Of Network | 3P + N + E |
Power Consumption In Va | 38 VA 480 V AC |
Power Consumption In Va | 80 VA 480 V AC |
Display Type | Without display |
Sampling Rate | 1024 samples/cycle |
Measurement Current | 0.01…20 A |
Input Type | voltage 5 MOhm) 5 current 0.3 mOhm) |
Measurement Voltage | 57…400 V AC 42...69 Hz between phase and neutral 100…690 V AC 42...69 Hz between phases |
Frequency Measurement Range | 20…450 Hz |
Number Of Inputs | 8 digital 30 V AC/60 V DC |
Measurement Accuracy | Voltage +/- 0.1 % Current +/- 0.1 % |
Accuracy Class | Class 0.1S active energy IEC 62053-22 Class 0.1 active energy IEC 61557-12 Class 0.1 active energy ANSI C12.20 Class 0.5S reactive energy IEC 62053-24 Class 0.1 current IEC 61557-12 Class 0.1 voltage IEC 61557-12 Class 0.1 active power IEC 61557-12 Class 0.5 power factor IEC 61557-12 |
Number Of Outputs | 4 digital 2 form C relay |
Communication Port Protocol | Modbus RTU 2400...115200 bps - 2-wire ION 2400...115200 bps - 2-wire DNP3 2400...115200 bps - 2-wire Modbus TCP 10/100 Mbit/s ION TCP 10/100 Mbit/s DNP3 TCP 10/100 Mbit/s IEC 61850 Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s DHCP DNS DLMS |
Communication Port Support | 2 RS485 removable screw terminal block |
Port Ethernet | 10/100BASE-TX 2 RJ45 |
Communication Gateway | Ethernet/serial |
Time Synchronisation Protocol | GPS IRIG-B NTP SNTP PTP |
Data Recording | Time stamping Min/max of instantaneous values User-definable data logs Continuous logging or snapshot Trending/forecasting Event logs Alarm logs Configuration change Power outage User login/logout Data logs GPS synchronisation Sequence of event recording |
Memory Capacity | 2 GB |
Cybersecurity | Syslog protocol support Robust security logs Port hardening Enable/disable communication ports Hardware metrology lock |
Web Services | Viewing of captured waveform Web page Pass/fail report for IEEE 519 Pass/fail report for EN 50160 ITIC (CBEMA) curve SEMI curve NEMA motor derating curve Alarm notification by e-mail TLS 1.2 Push historical data via mail |
Ethernet Service | DHCP client Device Profile Web Services (DPWS) Rapid Scanning Tree Protocol (RSTP) FTP/HTTP/HTTPS |
Communication Service | Compliant reports Power quality summary Energy report EcoStruxure Power Events Analysis SMTP e-mail notification SNMP |
Tamperproof Of Settings | Protected by sealable cover |
Mounting Support | DIN rail |
Electrical Insulation Class | Class III EN/IEC 62052-11 |
ISOlation Voltage | III, 400…690 V EN 61010-1:ed. 3 III, 347…600 V UL 61010-1:ed. 3 III, 347…600 V CSA C22.2 No 61010-1:ed. 3 |
Width | 6.30 in (160 mm) |
Depth | 5.33 in (135.3 mm) |
Height | 6.30 in (160 mm) |
Product Weight | 3.31 lb(US) (1.5 kg) |
Electromagnetic Compatibility | EMC immunity IEC 62052-11 EMC immunity IEC 61326-1 EMC immunity IEC 61000-6-5 Electrostatic discharge immunity test IEC 61000-4-2 Immunity to radiated fields IEC 61000-4-3 Immunity to fast transients IEC 61000-4-4 Surge immunity test IEC 61000-4-5 Immunity to conducted disturbances IEC 61000-4-6 Immunity to magnetic fields at network frequency IEC 61000-4-8 Immunity to conducted disturbances 2...150 kHz CLC/TR 50579 Voltage dips and interruptions immunity test IEC 61000-4-11 Immunity to impulse waves IEC 61000-4-12 Conducted and radiated emissions EN 55011 Conducted and radiated emissionsclass B EN 55032 Conducted and radiated emissionsclass B FCC part 15 Conducted and radiated emissionsclass B ICES-003 Surge withstand ANSI C37.90.1 Surge withstand IEEE C37.90.1 |
IP Degree Of Protection | Front IP65 Rear IP30 |
Degree Of Protection | UL type 12, front |
Relative Humidity | 5…95 % |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Installation Category | III |