Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
PowerLogic EM4900 Multi-Circuit Meter – 14x3P circuits – Modbus RTU only
METSEEM4914A
PowerLogic EM4900 Multi-Circuit Meter – 14x3P circuits – Modbus RTU only

This multi-circuit power meter is part of the PowerLogic EM4900 Series. This device is a multi-circuit power meters that make it easy to add many revenue-grade metering points. Without having to purchase, mount, wire and commission individual energy meters. This version measures current, voltage, power and energy consumption of up to 14 3-phase circuits with one board configuration. It offers Modbus RTU communications. Measurement accuracy is plus or minus 1 % with LVCT0xxxx0S split core, or plus or minus 0.5 % with LVCT2xxxx0S split core. The printed board can be installed in a panel. Mechanical dimensions of the base board are 226 mm in width, 146 mm in height and 71 mm in depth.

Add to Quote Catalogue
Specifications
Part Number METSEEM4914A
UPC 785901021452
UPC11 78590102145
EAN 0785901021452
Availability N
Lead Time 15
UNSPSC 83101808
Prop 65 This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov
Discount Schedule PL1
Return Indicator No
Depth 5.75 inch
Width 11.34 inch
Weight 3.31 pound
Characteristics
Range PowerLogic
Product Or Component Type Multi-circuit energy meter
Product Name PowerLogic EM4900
Device Short Name EM4914
Power Monitoring Basic instrumentation
Energy Management Sub billing and cost allocation Billing analysis
Device Application Sub billing
Type Of Measurement Current per phase, rms Current average Phase angle Active power total Active power per phase Apparent power total Apparent power per phase Power factor average Power factor per phase Active energy
Metering Type Demand power P Demand current I1, I2, I3, peak demand current IM1, IM2, IM3
[Us] Rated Supply Voltage 100...277 V AC 50/60 Hz
Network Frequency 50 Hz 60 Hz
Sampling Rate 256 samples/cycle
Current Transformer Input 42 solid core CT 0.333 V single pole 21 solid core CT 0.333 V single phase 14 solid core CT 0.333 V three phase 42 split core CT 0.333 V single pole 21 split core CT 0.333 V single phase 14 split core CT 0.333 V three phase
Measurement Voltage 150…480 V AC 50/60 Hz between phases 90…277 V AC 50/60 Hz between phase and neutral
Measurement Accuracy Power +/- 0.5 % of the measuring range Energy +/- 0.5 % of the measuring range Current +/- 0.5 % of the measuring range Voltage +/- 0.5 % of the measuring range
Communication Port Protocol Modbus RTU 9600, 19200, 38400 bps even/odd or none - 2 or 4 wires
Communication Port Support RS485 screw block terminal
Data Update Rate 2 s Modbus) 14 s BACnet) 20 s SNMP)
Data Recording Maximum of demand active power Maximum of instantaneous current Maximum of demand current
Communication Of Data High current alarm Low current alarm Total energy High-high current alarm Under voltage alarm Over voltage alarm Low-low current alarm
Communication Service Updating firmware
Mounting Mode Wall mount
Installation Category III
Pollution Degree 2
Ambient Air Temp For Op 32…140 °F (0…60 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Standards IEC 61010 UL 508
Width 11.34 in (288 mm)
Depth 5.75 in (146 mm)
Product Weight 3.31 lb(US) (1.5 kg)
Category 09793 - PLOGIC BRANCH CIRCUIT BCPM & MCM
Discount Schedule PL1
GTIN 00785901021452
Nbr. Of Units In Pkg. 1
EU RoHs Directive Compliant
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews