This multi-circuit power meter is part of the PowerLogic EM4900 Series. This device is a multi-circuit power meters that make it easy to add many revenue-grade metering points. Without having to purchase, mount, wire and commission individual energy meters. This version measures current, voltage, power and energy consumption of up to 14 3-phase circuits with one board configuration. It also offers Ethernet and serial communications. Measurement accuracy is plus or minus 1 % with LVCT0xxxx0S split core, or plus or minus 0.5 % with LVCT2xxxx0S split core. The printed board is installed in a sturdy metal enclosure. Mechanical dimensions of the main unit are 253 mm in width, 353 mm in height and 71 mm in depth.
Add to Quote CataloguePart Number | METSEEM4914E |
---|---|
UPC | 785901021483 |
UPC11 | 78590102148 |
EAN | 0785901021483 |
Availability | N |
Lead Time | 15 |
UNSPSC | 83101808 |
Prop 65 | This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov |
Discount Schedule | PL1 |
Return Indicator | No |
Depth | 12.09 inch |
Height | 2.76 inch |
Width | 9.96 inch |
Weight | 3.31 pound |
Range | PowerLogic |
---|---|
Product Or Component Type | Multi-circuit energy meter |
Product Name | PowerLogic EM4900E |
Device Short Name | EM4914 |
Power Monitoring | Basic instrumentation |
Energy Management | Sub billing and cost allocation Billing analysis |
Device Application | Sub billing |
Type Of Measurement | Current per phase, rms Current average Phase angle Active power total Active power per phase Apparent power total Apparent power per phase Power factor average Power factor per phase Active energy |
Metering Type | Demand current I1, I2, I3, peak demand current IM1, IM2, IM3 Demand power P |
[Us] Rated Supply Voltage | 100...277 V AC 50/60 Hz |
Network Frequency | 60 Hz 50 Hz |
Sampling Rate | 256 samples/cycle |
Current Transformer Input | 42 solid core CT 0.333 V single pole 21 solid core CT 0.333 V single phase 14 solid core CT 0.333 V three phase 42 split core CT 0.333 V single pole 21 split core CT 0.333 V single phase 14 split core CT 0.333 V three phase |
Measurement Voltage | 150…480 V AC 50/60 Hz between phases 90…277 V AC 50/60 Hz between phase and neutral |
Measurement Accuracy | Power +/- 0.5 % of the measuring range Energy +/- 0.5 % of the measuring range Current +/- 0.5 % of the measuring range Voltage +/- 0.5 % of the measuring range |
Communication Port Protocol | Modbus RTU 9600, 19200, 38400 bps even/odd or none - 2 wires Modbus TCP 9600, 19200, 38400 bps even/odd or none - 2 wires SNMP BACnet IP 10, 100 Mbits BACnet MS/TP |
Communication Port Support | Spring connector RS485 RJ45 |
Data Update Rate | 2 s Modbus) 14 s BACnet) 20 s SNMP) |
Data Recording | Maximum of instantaneous current Maximum of demand current Maximum of demand active power |
Communication Of Data | Low current alarm Low-low current alarm Over voltage alarm Under voltage alarm High current alarm High-high current alarm Total energy |
Web Services | Web server |
Communication Service | Updating firmware |
Mounting Mode | Wall mount |
Installation Category | III |
Pollution Degree | 2 |
Ambient Air Temp For Op | 32…140 °F (0…60 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Standards | UL 508 IEC 61010 |
Width | 9.96 in (253 mm) |
Depth | 12.09 in (307 mm) |
Height | 2.76 in (70 mm) |
Product Weight | 3.31 lb(US) (1.5 kg) |
Category | 09793 - PLOGIC BRANCH CIRCUIT BCPM & MCM |
Discount Schedule | PL1 |
GTIN | 00785901021483 |
Nbr. Of Units In Pkg. | 1 |
EU RoHs Directive | Compliant |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366