The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. 2 pulse outputs to communicate active and reactive energy, and 1 normaly closed contact for alarm. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.

Add to Quote Catalogue
Specifications
Part Number METSEEM3502
EAN 3606481969255
Availability N
Lead Time 14
UNSPSC 39121106
Prop 65 This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov
Discount Schedule PL1
Return Indicator No
Depth 2.32 inch
Height 3.58 inch
Width 4.21 inch
Characteristics
Range PowerLogic
Range Of Product PowerLogic EM3500
Device Short Name EM3502
Product Or Component Type Energy meter
Metering Type Demand power P, Q, S Peak demand power PM, QM, SM Current I1, I2, I3, Iavg Voltage U21, U32, U13, V1, V2, V3
Poles Description 3P + N
Type Of Measurement Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency
Device Application Partial meter Sub billing
Accuracy Class Class 0.2S power IEC 62053-22 Class 0.2S energy IEC 62053-22 Class 0.2S power ANSI C12.20 Class 0.2S energy ANSI C12.20
Measurement Accuracy Power +/- 0.2 % Energy +/- 0.2 %
Input Type split core current transducer 0.333 V or 1 V
Rated Voltage 90…347 V
Network Frequency 60 Hz 50 Hz
Technology Type Electronic
Display Type Backlit LCD
Measurement Current 5…32000 A
Display Digits 5
Information Displayed Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage
Tamperproof Of Settings Protected by access code
Communication Service Total cumulated active energy Total cumulated energy
Data Recording Energy consumption logs
Demand Intervals Fixed or rolling block
Local Signalling Red LED threshold reached Green flashing LED output signal
Number Of Outputs 2 pulse 1 alarm output
Output Voltage 30 V AC/DC
Ue Rated Operational Voltage 90...347 V AC 50/60 Hz between phase and neutral UL 156...600 V AC 50/60 Hz between phases UL 90...300 V AC 50/60 Hz between phase and neutral CE 125...300 V DC
Power Consumption In Va 5 VA 347 V AC between phase and neutral) 5 VA 600 V AC between phases)
Power Consumption In W 3 W 300 V
Ride-Through Time 100 ms 120 V AC
Mounting Mode Clip-on By screws
Mounting Support DIN rail
Standards UL 508 CSA C22.2 No 14-05 IEC 61010-1
Product Certifications CE IEC 61010 CULus UL 508
Relative Humidity 0…95 %
Ambient Air Temp For Op -22…158 °F (-30…70 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
Colour Dark grey
9 mm Pitches 12
Width 4.21 in (107 mm)
Height 3.58 in (91 mm)
Depth 2.32 in (59 mm)
Category 09798 - POWERLOGIC EM3500 SERIES
Discount Schedule PL1
Nbr. Of Units In Pkg. 1
EU RoHs Directive Not compliant
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.