The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. 2 pulse outputs to communicate active and reactive energy, and 1 normaly closed contact for alarm. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.
Add to Quote CataloguePart Number | METSEEM3502 |
---|---|
EAN | 3606481969255 |
Availability | N |
Lead Time | 14 |
UNSPSC | 39121106 |
Prop 65 | This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov |
Discount Schedule | PL1 |
Return Indicator | No |
Depth | 2.32 inch |
Height | 3.58 inch |
Width | 4.21 inch |
Range | PowerLogic |
---|---|
Range Of Product | PowerLogic EM3500 |
Device Short Name | EM3502 |
Product Or Component Type | Energy meter |
Metering Type | Demand power P, Q, S Peak demand power PM, QM, SM Current I1, I2, I3, Iavg Voltage U21, U32, U13, V1, V2, V3 |
Poles Description | 3P + N |
Type Of Measurement | Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency |
Device Application | Partial meter Sub billing |
Accuracy Class | Class 0.2S power IEC 62053-22 Class 0.2S energy IEC 62053-22 Class 0.2S power ANSI C12.20 Class 0.2S energy ANSI C12.20 |
Measurement Accuracy | Power +/- 0.2 % Energy +/- 0.2 % |
Input Type | split core current transducer 0.333 V or 1 V |
Rated Voltage | 90…347 V |
Network Frequency | 60 Hz 50 Hz |
Technology Type | Electronic |
Display Type | Backlit LCD |
Measurement Current | 5…32000 A |
Display Digits | 5 |
Information Displayed | Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage |
Tamperproof Of Settings | Protected by access code |
Communication Service | Total cumulated active energy Total cumulated energy |
Data Recording | Energy consumption logs |
Demand Intervals | Fixed or rolling block |
Local Signalling | Red LED threshold reached Green flashing LED output signal |
Number Of Outputs | 2 pulse 1 alarm output |
Output Voltage | 30 V AC/DC |
Ue Rated Operational Voltage | 90...347 V AC 50/60 Hz between phase and neutral UL 156...600 V AC 50/60 Hz between phases UL 90...300 V AC 50/60 Hz between phase and neutral CE 125...300 V DC |
Power Consumption In Va | 5 VA 347 V AC between phase and neutral) 5 VA 600 V AC between phases) |
Power Consumption In W | 3 W 300 V |
Ride-Through Time | 100 ms 120 V AC |
Mounting Mode | Clip-on By screws |
Mounting Support | DIN rail |
Standards | UL 508 CSA C22.2 No 14-05 IEC 61010-1 |
Product Certifications | CE IEC 61010 CULus UL 508 |
Relative Humidity | 0…95 % |
Ambient Air Temp For Op | -22…158 °F (-30…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Colour | Dark grey |
9 mm Pitches | 12 |
Width | 4.21 in (107 mm) |
Height | 3.58 in (91 mm) |
Depth | 2.32 in (59 mm) |
Category | 09798 - POWERLOGIC EM3500 SERIES |
Discount Schedule | PL1 |
Nbr. Of Units In Pkg. | 1 |
EU RoHs Directive | Not compliant |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366