The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.
Add to Quote CataloguePart Number | METSEEM3550 |
---|---|
UPC | 785901302605 |
UPC11 | 78590130260 |
EAN | 0785901302605 |
Availability | N |
Lead Time | 14 |
UNSPSC | 39121107 |
Prop 65 | This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | PL1 |
Return Indicator | Yes |
Depth | 2.32 inch |
Height | 3.58 inch |
Width | 4.21 inch |
Range | PowerLogic |
---|---|
Range Of Product | PowerLogic EM3500 |
Device Short Name | EM3550 |
Product Or Component Type | Energy meter |
Metering Type | Voltage U21, U32, U13, V1, V2, V3 Peak demand power PM, QM, SM Demand power P, Q, S Current I1, I2, I3, Iavg |
Poles Description | 3P + N |
Type Of Measurement | Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency |
Device Application | Sub billing Partial meter |
Accuracy Class | Class 0.5S power IEC 62053-22 Class 0.5S energy IEC 62053-22 Class 0.5S power ANSI C12.20 Class 0.5S energy ANSI C12.20 |
Measurement Accuracy | Power +/- 0.5 % Energy +/- 0.5 % |
Input Type | split core current transducer 0.333 V or 1 V |
Rated Voltage | 90…347 V |
Network Frequency | 50 Hz 60 Hz |
Technology Type | Electronic |
Display Type | Backlit LCD |
Measurement Current | 5…32000 A |
Display Digits | 5 |
Information Displayed | Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage |
Tamperproof Of Settings | Protected by access code |
Communication Port Protocol | Modbus RTU 1200…38400 bps - 2-wire |
Communication Port Support | Screw terminal block RS485 |
Communication Service | Total cumulated energy Total cumulated active energy |
Data Recording | Energy consumption logs |
Demand Intervals | Fixed or rolling block External synchronisation to communication |
Local Signalling | Red LED threshold reached Green flashing LED output signal |
Number Of Outputs | 1 alarm output 1 pulse |
Power Consumption In W | 3 W 300 V |
Mounting Mode | Clip-on By screws |
Mounting Support | DIN rail |
Standards | UL 508 IEC 61010-1 CSA C22.2 No 14-05 |
Product Certifications | CE IEC 61010 CULus UL 508 |
Relative Humidity | 0…95 % |
Ambient Air Temp For Op | -22…158 °F (-30…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Colour | Dark grey |
9 mm Pitches | 12 |
Width | 4.21 in (107 mm) |
Height | 3.58 in (91 mm) |
Depth | 2.32 in (59 mm) |
Category | 09798 - POWERLOGIC EM3500 SERIES |
Discount Schedule | PL1 |
GTIN | 00785901302605 |
Nbr. Of Units In Pkg. | 1 |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |