The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xxA models are designed for use exclusively with Rogowski coil CTs where integrator and power supply for the CTs are built into the meter. Not recommanded for high harmonic application. Current input from 20A to 5000A with the Rogowski coil, ANSI C12.20 0.5% accuracy, IEC 62053-22 class 0.5S. The data logging capability protects data in the event of a power failure. Native BACnet and phase alarms are all provided to suit a wide variety of applications. Additional pulse input provide an easy way to incorporate simple WAGES sensors using a BACnet system. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm and product weight 280 g.
Brand: Square D
Add to Quote CataloguePart Number | METSEEM3560A |
---|---|
Availability | N |
Lead Time | 14 |
UNSPSC | 39121032 |
Prop 65 | This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | PL1 |
Return Indicator | Yes |
Depth | 2.32 inch |
Height | 3.58 inch |
Width | 4.21 inch |
Range | PowerLogic |
---|---|
Range Of Product | PowerLogic EM3500 |
Device Short Name | EM3560A |
Product Or Component Type | Energy meter |
Metering Type | Peak demand power PM, QM, SM Current I1, I2, I3, Iavg Demand power P, Q, S Voltage U21, U32, U13, V1, V2, V3 |
Poles Description | 3P + N |
Type Of Measurement | Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency |
Device Application | Sub billing Partial meter |
Accuracy Class | Class 0.5S power IEC 62053-22 Class 0.5S energy IEC 62053-22 Class 0.5S power ANSI C12.20 Class 0.5S energy ANSI C12.20 |
Measurement Accuracy | Power +/- 0.5 % Energy +/- 0.5 % |
Input Type | Rogowski coil 50...5000 A |
Rated Voltage | 90…347 V |
Network Frequency | 50 Hz 60 Hz |
Technology Type | Electronic |
Display Type | Backlit LCD |
Measurement Current | 20…5000 A |
Display Digits | 5 |
Information Displayed | Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage |
Tamperproof Of Settings | Protected by access code |
Communication Port Protocol | BACnet MS/TP 9600 bauds...115200 bauds (automatic detection) - 2-wire |
Communication Port Support | Screw terminal block RS485 |
Communication Service | Total cumulated energy Total cumulated active energy |
Data Recording | Energy consumption logs |
Demand Intervals | External synchronisation to communication Fixed or rolling block |
Local Signalling | Red LED threshold reached Green flashing LED output signal |
Number Of Accumulator Inputs | 1 pulse |
Number Of Outputs | 1 alarm output |
Buffer Size | 32-bit 3 |
Ue Rated Operational Voltage | 90...347 V AC 50/60 Hz between phase and neutral UL 156...600 V AC 50/60 Hz between phases UL 90...300 V AC 50/60 Hz between phase and neutral CE 125...300 V DC |
Power Consumption In Va | 5 VA 347 V AC between phase and neutral) 5 VA 600 V AC between phases) |
Power Consumption In W | 3 W 300 V |
Ride-Through Time | 100 ms 120 V AC |
Mounting Mode | By screws Clip-on |
Mounting Support | DIN rail |
Standards | IEC 61010-1 UL 508 CSA C22.2 No 14-05 |
Product Certifications | CE IEC 61010 CULus UL 508 |
Relative Humidity | 0…95 % |
Ambient Air Temp For Op | -22…158 °F (-30…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Colour | Dark grey |
9 mm Pitches | 12 |
Width | 4.21 in (107 mm) |
Height | 3.58 in (91 mm) |
Depth | 2.32 in (59 mm) |
Category | 09798 - POWERLOGIC EM3500 SERIES |
Discount Schedule | PL1 |
Nbr. Of Units In Pkg. | 1 |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366