| Part Number | XCSPA292 |
|---|---|
| UPC | 389119028486 |
| UPC11 | 38911902848 |
| EAN | 3389119028486 |
| Availability | N |
| Lead Time | 20 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | T |
| Return Indicator | No |
| Depth | 1.18 inch |
| Height | 3.70 inch |
| Width | 1.18 inch |
| Weight | 0.24 pound |
| Range Of Product | Preventa Safety detection |
|---|---|
| Product Or Component Type | Safety switch |
| Component Name | XCSPA |
| Design | Compact |
| Material | Plastic |
| Head Type | Key operated turret head |
| Contacts Type And Composition | 2 NC |
| Contact Operation | Snap action |
| Cable Entry | 1 entry tapped M16 x 1.5 |
| Cable Outer Diameter | 0.28…0.39 in (7…10 mm) |
| Electrical Connection | Terminal 1 x 0.34...2 x 1.5 mm² |
| Number Of Poles | 2 |
| Locking Options Description | Without locking of actuator |
| Insulation | Double insulated |
| Positive Opening | With NC contact |
| Mechanical Durability | 1000000 cycles |
| Positive Opening Min Force | 15 N |
| Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
| Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
| Ie Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 |
| Ithe Cnvtl Enclosed Therm Crrt | 10 A |
| Ui Rated Insulation Voltage | 300 VUL 508 500 VEN/IEC 60947-1 300 VCSA C22.2 No 14 |
| Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-5-1 |
| Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
| Actutr Forcible Withdrawal Rtc | 10 N |
| Operating Rate | 10 cyc/mn for maximum durability |
| Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
| Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
| Body Material | PA (polyamide) |
| Head Material | PA (polyamide) |
| Depth | 1.18 in (30 mm) |
| Height | 3.70 in (94 mm) |
| Width | 1.18 in (30 mm) |
| Product Weight | 0.24 lb(US) (0.11 kg) |
| Standards | EN/IEC 60204-1 EN 1088/ISO 14119 EN/ISO 12100 CSA C22.2 No 14 UL 508 EN/IEC 60947-5-1 |
| Product Certifications | UL CSA |
| Protective Treatment | TC |
| Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Vibration Resistance | 5 gn 10…500 Hz)IEC 60068-2-6 |
| Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
| Electrical Shock Protect Class | Class II EN/IEC 61140 |
| IP Degree Of Protection | IP67 EN/IEC 60529 IP67 EN/IEC 60947-5-1 |
| Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
| Discount Schedule | T |
| GTIN | 03389119028486 |
| Nbr. Of Units In Pkg. | 1 |
| Green Premium Status | Green Premium product |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366