This Zelio RM17-U control relay allows monitoring of overvoltage control. This modular control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems: ideal for refurbishment of old installations without using a PLC.
Add to Quote Catalogue| Part Number | RM22UA21MR |
|---|---|
| Country of Origin | ID |
| UPC | 785901016540 |
| UPC11 | 78590101654 |
| EAN | 3606480792205 |
| Availability | N |
| Lead Time | 43 |
| UNSPSC | 39122329 |
| HTs Code | 8536410060 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | CP2 |
| Return Indicator | No |
| Width | 0.89 inch |
| Weight | 0.24 pound |
| Range Of Product | Zelio Control |
|---|---|
| Product Or Component Type | Modular measurement and control relays |
| Relay Type | Voltage control relay |
| Network Number Of Phases | 1 phase |
| Supply Circuit Type | DC |
| Relay Name | RM22UA |
| Relay Monitored Parameters | Overvoltage detection |
| Time Delay Type | Without |
| Switching Capacity In Va | 2000 VA |
| Measurement Range | 50 mV...5 V voltage AC/DC 50/60 Hz |
| Reset Time | 1500 ms at maximum voltage |
| Maximum Switching Voltage | 250 V AC |
| Minimum Switching Current | 10 mA 5 V DC |
| Maximum Switching Current | 8 A AC |
| [Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
| Supply Voltage Limits | 20.4…264 V AC/DC |
| Power Consumption In Va | 3.5 VA AC |
| Power Consumption In W | 1.5 W DC |
| Supply Voltage Frequency | 40...70 Hz +/- 10 % |
| Resistance Across Terminals | 30 kOhm E2-M terminals 5 kOhm E1-M terminals 50 kOhm E3-M terminals |
| Output Contacts | 2 C/O |
| Hysteresis | 5…50 % adjustable threshold setting |
| Run-Up Delay At Power-Up | 600 ms |
| Measuring Cycle | 100 ms measurement cycle as true rms value |
| Repeat Accuracy | +/- 0.5 % input and measurement circuit |
| Measurement Error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
| Response Time | <= 500 ms |
| Overvoltage Category | III IEC 60664-1 |
| Insulation Resistance | > 100 MOhm 500 V DC IEC 60255-27 |
| Insulation | Between supply and measurement |
| Mounting Position | Any position |
| Connections - Terminals | Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
| Tightening Torque | 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1 |
| Housing Material | Self-extinguishing plastic |
| Status Led | Relay ON LED Yellow) Power ON LED Green) |
| Mounting Support | 35 mm DIN rail EN/IEC 60715 |
| Electrical Durability | 100000 cycles |
| Mechanical Durability | 10000000 cycles |
| Utilisation Category | AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1 |
| Safety Reliability Data | B10d = 290000 MTTFd = 308.2 years |
| Contacts Material | Cadmium free |
| Width | 0.89 in (22.5 mm) |
| Product Weight | 0.24 lb(US) (0.11 kg) |
| Immunity To Microbreaks | 10 ms |
| Electromagnetic Compatibility | Immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 Immunity for industrial environments EN/IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Emission standard for industrial environments EN/IEC 61000-6-4 Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 Surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 Surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 Conducted and radiated emissionsclass B group 1 CISPR 11 Conducted and radiated emissionsclass B CISPR 22 |
| Standards | EN/IEC 60255-1 |
| Product Certifications | UL China RoHS EAC CSA GL CCC RCM CE |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Ambient Air Temp For Op | -4…122 °F (-20…50 °C) 60 Hz -4…140 °F (-20…60 °C) 50 Hz AC/DC |
| Relative Humidity | 93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30 |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366