Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
On-delay Timing Relay – 0.05s…300h – 24…240V AC/DC – 2C/O
RE22R2AMR
On-delay Timing Relay – 0.05s…300h – 24…240V AC/DC – 2C/O

This Zelio RE22 modular dual function timer can be set between 1 seconds and 300 hours. It provides function A and function Aw and it is mountable on DIN rail. This modular dual function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Dual function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.

Add to Quote Catalogue
Specifications
Part Number RE22R2AMR
Country of Origin ID
UPC 785901311263
UPC11 78590131126
EAN 3606480792472
Availability N
Lead Time 43
UNSPSC 39121523
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CP2
Return Indicator Yes
Width 0.89 inch
Weight 0.23 pound
Characteristics
Range Of Product Zelio Time
Product Or Component Type Modular timing relay
Discrete Output Type Relay
Device Short Name RE22
Nominal Output Current 8 A
Contacts Type And Composition 1 C/O timed contact, cadmium free 1 C/O timed or instantaneous contact, cadmium free
Time Delay Type Aw A
Time Delay Range 0.05...1 s 0.3...3 s 3...30 h 30...300 min 10...100 s 30...300 s 3...30 s 30...300 h 1...10 s 3...30 min
Control Type Rotary knob Diagnostic button Potentiometer external
[Us] Rated Supply Voltage 24...240 V AC/DC 50/60 Hz
Release Input Voltage <= 2.4 V
Voltage Range 0.85...1.1 Us
Supply Frequency 50...60 Hz +/- 5 %
Connections - Terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Tightening Torque 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
Housing Material Self-extinguishing
Repeat Accuracy +/- 0.5 % IEC 61812-1
Temperature Drift +/- 0.05 %/°C
Voltage Drift +/- 0.2 %/V
Setting Accuracy Of Time Delay +/- 10 % of full scale 25 °C IEC 61812-1
Control Signal Pulse Width 100 ms with load in parallel 30 ms
Insulation Resistance 100 MOhm 500 V DC IEC 60664-1
Recovery Time 120 ms on de-energisation
Immunity To Microbreaks 10 ms
Power Consumption In Va 3 VA 240 V AC
Power Consumption In W 1.5 W 240 V DC
Switching Capacity In Va 2000 VA
Minimum Switching Current 10 mA 5 V DC
Maximum Switching Current 8 A
Maximum Switching Voltage 250 V AC
Electrical Durability 100000 cycles, 8 A 250 V, AC-1 100000 cycles, 2 A 24 V, DC-1
Mechanical Durability 10000000 cycles
Rated Impulse Withstand Voltage 5 kV 1.2…50 µs IEC 60664-1
Power On Delay 100 ms
Creepage Distance 4 kV/3 IEC 60664-1
Overvoltage Category III IEC 60664-1
Safety Reliability Data B10d = 200000 MTTFd = 216.8 years
Mounting Position Any position
Mounting Support 35 mm DIN rail EN/IEC 60715
Status Led Green LED backlight steady)dial pointer indication Yellow LED steady)output relay energised Yellow LED fast flashing)timing in progress and output relay de-energised Yellow LED slow flashing)timing in progress and output relay energised
Width 0.89 in (22.5 mm)
Product Weight 0.23 lb(US) (0.105 kg)
Dielectric Strength 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Standards UL 508 IEC 61812-1
Directives 2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive
Product Certifications CE CCC GL China RoHS UL RCM EAC CSA
Ambient Air Temp For Op -4…140 °F (-20…60 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
IP Degree Of Protection Housing IP40 IEC 60529 Terminals IP20 IEC 60529 Front panel IP50 IEC 60529
Pollution Degree 3 IEC 60664-1
Documents