Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
NFC 3-phase monitoring relay, 8 A, 2CO, multifunction, 208…480 V AC
RMNF22TB30
NFC 3-phase monitoring relay, 8 A, 2CO, multifunction, 208…480 V AC

This 3 phase control relay is integrated with NFC technology which brings digital instead of analog operation. The features in the relay allows user to easily monitor the relay or change settings hence saving time and boosting efficiency. The 3 phase NFC control relay enables in-time detection of electrical network faults and indicates the need for maintenance or corrective operations. This helps to increase motor life, reduce the need for motor repair or replacement and minimize motor downtime.

Add to Quote Catalogue
Specifications
Part Number RMNF22TB30
EAN 3606489591120
Availability N
Lead Time 35
RoHS Compliant Yes
Discount Schedule CP2
Depth 3.90 inch
Height 3.54 inch
Width 0.89 inch
Weight 0.28 pound
Characteristics
Range Of Product Zelio Control
Product Or Component Type Monitoring relay
Relay Type Control relay
Network Number Of Phases 3 phase
Relay Name RMNF22
Relay Monitored Parameters Phase sequence Phase failure detection Overvoltage detection Undervoltage detection Overfrequency and underfrequency Asymmetry
Supported Os Android
Software Version V4.4 and above
App For Product Zelio NFC downloadable from Google Play store)
Product Compatibility NFC enabled mobile device
Time Delay Type On-delay 0.1 s...60 min Off-delay 0.1 s...60 min
Switching Capacity In Va 2000 VA
Nfc Operating Frequency 13.56 MHz
Maximum Rf Power Transmitted 0.0002 mW
Reset Time 1500 ms at maximum voltage
Maximum Switching Voltage 250 V AC
Minimum Switching Current 100 mA 6 V
Maximum Switching Current 8 A AC
Us Rated Supply Voltage 208...480 V AC line to line 120...277 V AC line to neutral
Supply Voltage Limits 166.4…576 V AC line to line 96…332.4 V AC line to neutral
Power Consumption In Va 4 VA 480 V AC 60 Hz
On-Load Factor 100 %
Supply Voltage Frequency 50...60 Hz +/- 10 %
Output Contacts 2 C/O
Setg Accr Of The Swting Thrhld +/- (1.5 % + 1 V)
Setting Accuracy Of Time Delay +/- 3 % 10 s...60 min +/- 300 ms 0...10 s
Hysteresis 3 % fixed phase failure detection
Alarm Threshold 166...576 V adjustable overvoltage and undervoltage detection (line to line) 96...332 V adjustable overvoltage and undervoltage detection (line to neutral) 5...150 V adjustable asymmetry 45...66 Hz adjustable overfrequency or underfrequency
Run-Up Delay At Power-Up Max 650 ms
Measuring Cycle 150 ms measurement cycle as true rms value
Repeat Accuracy +/- 0.5 % input circuit +/- 3 % time delay
Measurement Error < 0.05 %/Hz with frequency variation < 0.05 %/°C with temperature variation
Response Time <= 300 ms
Insulation Resistance > 100 MOhm 500 V DC IEC 60255-27
Ui Rated Insulation Voltage 400 V
Uimp Rated Imp Wstd Voltage 4 kV 1.2/50 µs
Dielectric Test Voltage 2.5 kV AC 50 Hz, 1 min IEC 60255-27
Mounting Position Any position
Connections - Terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.5...2 x 1.5 mm² AWG 20...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.5...1 x 2.5 mm² AWG 20...AWG 14) flexible with cable end
Tightening Torque 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1 5.3…8.8 lbf.in (0.60…0.99 N.m) IEC 60947-1
Housing Material Self-extinguishing plastic
Local Signalling Un, green LED steady)power ON R1, amber LED steady)relay energised R1, amber LED blinking)timing in progress R2, amber LED steady)relay energised R2, amber LED blinking)timing in progress PL, red LED steady)alarm phase failure triggered PS, red LED blinking)alarm phase sequence failure triggered UV, red LED steady)alarm undervoltage failure triggered OV, red LED blinking)alarm overvoltage failure triggered UF, red LED steady)alarm underfrequency failure triggered OF, red LED blinking)alarm overfrequency failure triggered ASYM, red LED steady)alarm asymmentry failure triggered
Mounting Support 35 mm DIN rail EN/IEC 60715
Electrical Durability 100000 cycles
Mechanical Durability 10000000 cycles
Utilisation Category AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1
Ith Cnvtl Free Air Therm Crrt 8 A
Contacts Material Cadmium free
Width 0.89 in (22.5 mm)
Height 3.54 in (90 mm)
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews