Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Multifunction Timer Relay – 12V AC/DC – 2 C/O
RE22R2MJU
Multifunction Timer Relay – 12V AC/DC – 2 C/O

This Zelio RE22 modular multi function timer can be set between 0.1 seconds and 100 hours. It provides multi functions and it is mountable on DIN rail. This modular multi function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.

Add to Quote Catalogue
Specifications
Part Number RE22R2MJU
Country of Origin ID
UPC 785901503842
UPC11 78590150384
EAN 3606480676598
Availability N
Lead Time 31
UNSPSC 39121523
HTs Code 8536490080
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CP2
Return Indicator No
Width 0.89 inch
Weight 0.20 pound
Characteristics
Range Of Product Zelio Time
Product Or Component Type Modular timing relay
Discrete Output Type Relay
Device Short Name RE22
Nominal Output Current 8 A
Contacts Type And Composition 1 C/O timed contact 1 C/O timed or instantaneous contact
Time Delay Type B C Di Ht Bw Ac H At A D
Time Delay Range 1...10 min 6...60 min 0.1...1 s 6...60 s 1...10 s 1...10 h 10...100 h
Control Type Rotary knob front panel
[Us] Rated Supply Voltage 12 V AC/DC
Voltage Range 0.9...1.2 Us
Supply Frequency 50...60 Hz +/- 5 %
Connections - Terminals Screw terminals, 2 x 1.5 mm² with cable end Screw terminals, 2 x 2.5 mm² without cable end
Tightening Torque 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
Housing Material Self-extinguishing
Repeat Accuracy +/- 0.5 % IEC 61812-1
Temperature Drift +/- 0.05 %/°C
Voltage Drift +/- 0.2 %/V
Setting Accuracy Of Time Delay +/- 10 % of full scale 25 °C IEC 61812-1
Control Signal Pulse Width 30 ms 100 ms under load
Insulation Resistance 100 MOhm 500 V DC IEC 60664-1
Recovery Time 120 ms on de-energisation
Immunity To Microbreaks 10 ms
Power Consumption In Va 1.2 VA 12 V AC
Power Consumption In W 0.5 W 12 V DC
Breaking Capacity 2000 VA
Minimum Switching Current 10 mA 5 V
Maximum Switching Current 8 mA
Maximum Switching Voltage 250 V
Electrical Durability 100000 cycles resistive, 8 A 250 V, AC
Mechanical Durability 10000000 cycles
Rated Impulse Withstand Voltage 5 kV 1.2…50 µs IEC 60664-1 5 kV IEC 61812-1
Power On Delay 100 ms
Safety Reliability Data B10d = 190000 MTTFd = 205.4 years
Mounting Position Any position in relation to normal vertical mounting plane
Mounting Support 35 mm DIN rail EN/IEC 60715
Status Led Green LED flashing)timing in progress Green LED steady)power ON Yellow LEDrelay energised
Width 0.89 in (22.5 mm)
Product Weight 0.20 lb(US) (0.09 kg)
Dielectric Strength 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
Standards EN 61000-6-1 IEC 61812-1 EN 61000-6-4 EN 61000-6-3 EN 61000-6-2
Directives 2006/95/EC - low voltage directive 2004/108/EC - electromagnetic compatibility
Product Certifications CSA CULus China RoHS CE EAC GL CCC RCM
Ambient Air Temp For Op -4…140 °F (-20…60 °C)
Ambient Air Temp For Storage -22…140 °F (-30…60 °C)
IP Degree Of Protection Housing IP40 IEC 60529 Terminal block IP20 IEC 60529 Front face IP40 IEC 60529
Vibration Resistance 20 m/s² 10…150 Hz)IEC 60068-2-6
Shock Resistance 15 gn 11 ms IEC 60068-2-27
Relative Humidity 93 %, without condensation IEC 60068-2-30
Electromagnetic Compatibility Electrostatic discharge immunity test 6 kV contact discharge)level 3 EN/IEC 61000-4-2 Electrostatic discharge immunity test 8 kV air discharge)level 3 EN/IEC 61000-4-2 Fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 Fast transients immunity test 2 kV direct contact)level 3 IEC 61000-4-4 Surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5 Surge immunity test 2 kV common mode)level 3 IEC 61000-4-5 Radiated radio-frequency electromagnetic field immunity test 10 V 0.15...80 MHz)level 3 IEC 61000-4-6 Electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 Immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11 Immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11 Conducted and radiated emissionsclass B EN 55022
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews