Part Number | MGN61529 |
---|---|
Country of Origin | CN |
UPC | 785901908753 |
UPC11 | 78590190875 |
EAN | 3606480056994 |
Availability | N |
Lead Time | 69 |
UNSPSC | 39121603 |
ECCN | EAR99 |
HTs Code | 8536200020 |
Discount Schedule | DE2 |
Return Indicator | No |
Depth | 2.87 inch |
Height | 3.19 inch |
Width | 1.42 inch |
Weight | 0.56 pound |
Range | Multi 9 |
---|---|
Product Name | Multi 9 C60H-DC |
Product Or Component Type | Miniature circuit-breaker |
Device Short Name | C60H-DC |
Device Application | Distribution |
Poles Description | 2P |
Number Of Protected Poles | 2 |
In Rated Current | 13 A 77 °F (25 °C) |
Network Type | DC |
Trip Unit Technology | Thermal-magnetic |
Curve Code | C |
Breaking Capacity | 20 kA Icu 220 V DC GB 14048.2 10 kA Icu 440 V DC GB 14048.2 6 kA Icu 500 V DC GB 14048.2 20 kA Icu 220 V DC EN/IEC 60947-2 10 kA Icu 440 V DC EN/IEC 60947-2 6 kA Icu 500 V DC EN/IEC 60947-2 5 kA AIR 12...500 V DC UL 1077 |
Utilisation Category | Category A EN/IEC 60947-2 |
Suitability For ISOlation | Yes EN/IEC 60947-2 |
Ue Rated Operational Voltage | 12...500 V DC |
Magnetic Tripping Limit | 8.5 x In +/- 20 % AC |
Ics Rated Service Breaking Cap | 4.5 kA 75 % GB 14048.2 - 500 V DC 7.5 kA 75 % GB 14048.2 - 440 V DC 15 kA 75 % GB 14048.2 - 220 V DC 15 kA 75 % EN/IEC 60947-2 - 220 V DC 7.5 kA 75 % EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % EN/IEC 60947-2 - 500 V DC |
Limitation Class | 3 EN/IEC 60947-2 |
Ui Rated Insulation Voltage | 500 V DC EN/IEC 60947-2 |
Uimp Rated Imp Wstd Voltage | 6 kVEN/IEC 60947-2 |
Contact Position Indicator | Yes |
Control Type | Toggle |
Local Signalling | ON/OFF indication |
Mounting Mode | Clip-on |
Mounting Support | DIN rail |
Comb Bb Distrib Blk Compatib | Top or bottom standard |
9 mm Pitches | 4 |
Height | 3.19 in (81 mm) |
Width | 1.42 in (36 mm) |
Depth | 2.87 in (73 mm) |
Product Weight | 0.56 lb(US) (0.256 kg) |
Colour | Gray |
Mechanical Durability | 20000 cycles |
Electrical Durability | 3000 cycles L/R = 2 ms 6000 cycles |
Provision For Padlocking | Padlockable |
Locking Options Description | In position O |
Connections - Terminals | Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 4) - rigid stranded Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…10 mm²) AWG 18...AWG 8) - rigid stranded Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…10 mm²) AWG 18...AWG 8) - flexible Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…10 mm²) AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal top or bottom) - 3 0.00 in² (1 mm²) AWG 18) - flexible stranded |
Wire Stripping Length | 0.55 in (14 mm) top or bottom |
Tightening Torque | 22.13 lbf.in (2.5 N.m) top or bottom |
Earth-Leakage Protection | Without |
Standards | UL 1077 GB 14048.2 EN/IEC 60947-2 |
Product Certifications | UR CCC IEC |
IP Degree Of Protection | IP20IEC 60529 IP40 modular enclosure)IEC 60529 |
Pollution Degree | 3 EN/IEC 60947-2 |
Overvoltage Category | IV |
Tropicalisation | 2 IEC 60068-2 2 GB 14048.2 |
Relative Humidity | 95 % 131 °F (55 °C) |
Operating Altitude | 6561.68 ft (2000 m) |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |