TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 24 VDC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
Add to Quote CataloguePart Number | LTMEV40BD |
---|---|
Country of Origin | CN |
UPC | 785901502395 |
UPC11 | 78590150239 |
EAN | 3389119404921 |
Availability | S |
Lead Time | 24 |
UNSPSC | 39122214 |
ECCN | EAR99 |
HTs Code | 8536308000 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 4.75 inch |
Height | 2.40 inch |
Width | 1.77 inch |
Weight | 0.46 pound |
Range | TeSys |
---|---|
Product Name | TeSys T |
Device Short Name | LTME |
Product Or Component Type | Extension module |
Device Application | Equipment monitoring and control |
Range Compatibility | TeSys T LTMR motor controller |
Supply | Via the controller |
Ui Rated Insulation Voltage | 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 |
Uimp Rated Imp Wstd Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
Logic Input Number | 4 |
Input Current | 7 mA |
Current State 0 Guaranteed | Logic input < 5 V <= 15 mA 5 ms |
Current State 1 Guaranteed | Logic input < 15 V 2...15 mA 15 ms |
Maximum Output Switching Frequency | 2 Hz |
Operating Rate | 1800 cyc/h |
Contacts Type And Composition | Without |
Metering Type | Voltage U21, U32, U13, V1, V2, V3 Imbalance voltage Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Reactive power Q, Q1, Q2, Q3 Power factor Active power P, P1, P2, P3 |
Measurement Accuracy | 1 % voltage 100...830 V) 3 % power factor 5 % active and reactive power |
Overvoltage Category | III |
Connection Pitch | 0.20 in (5.08 mm) |
Connections - Terminals | Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end |
Tightening Torque | Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm) |
Pollution Degree | 3 |
Electromagnetic Compatibility | Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) Conducted RF disturbances 10 V)EN/IEC 61000-4-6) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 4 kV)EN/IEC 61000-4-5) |
Width | 1.77 in (45 mm) |
Height | 2.40 in (61 mm) |
Depth | 4.75 in (120.7 mm) |
Product Weight | 0.46 lb(US) (0.21 kg) |
Compatibility Code | LTME |
Standards | IEC 60947-4-1 UL 508 EN 60947-4-1 IACS E10 CSA C22.2 No 14 |
Product Certifications | UL NOM ATEX BV CSA EAC RINA LROS (Lloyds register of shipping) DNV ABS GL KERI RMRoS C-tick CCC |
IP Degree Of Protection | IP20 |
Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068 |
Fire Resistance | 1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94 |
Ambient Air Temp For Op | -4…140 °F (-20…60 °C) |
Ambient Air Temp For Storage | -40…176 °F (-40…80 °C) |
Operating Altitude | <= 6561.68 ft (2000 m) without derating |
Mechanical Robustness | Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 |
Category | 22338 - SOLID STATE OVERLOAD RELAYS |
Discount Schedule | I12 |
GTIN | 00785901502395 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | CN |
Green Premium Status | Green Premium product |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Pvc Free | Yes |
Halogen Content Performance | Halogen free plastic parts product |
Warranty | 18 months |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366