Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Motor Management, TeSys T, extension module, 4 inputs, for LTMR controller, 24 VDC
LTMEV40BD
Motor Management, TeSys T, extension module, 4 inputs, for LTMR controller, 24 VDC

TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 24 VDC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Add to Quote Catalogue
Specifications
Part Number LTMEV40BD
Country of Origin CN
UPC 785901502395
UPC11 78590150239
EAN 3389119404921
Availability S
Lead Time 24
UNSPSC 39122214
ECCN EAR99
HTs Code 8536308000
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 4.75 inch
Height 2.40 inch
Width 1.77 inch
Weight 0.46 pound
Characteristics
Range TeSys
Product Name TeSys T
Device Short Name LTME
Product Or Component Type Extension module
Device Application Equipment monitoring and control
Range Compatibility TeSys T LTMR motor controller
Supply Via the controller
Ui Rated Insulation Voltage 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
Uimp Rated Imp Wstd Voltage 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Logic Input Number 4
Input Current 7 mA
Current State 0 Guaranteed Logic input < 5 V <= 15 mA 5 ms
Current State 1 Guaranteed Logic input < 15 V 2...15 mA 15 ms
Maximum Output Switching Frequency 2 Hz
Operating Rate 1800 cyc/h
Contacts Type And Composition Without
Metering Type Voltage U21, U32, U13, V1, V2, V3 Imbalance voltage Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Reactive power Q, Q1, Q2, Q3 Power factor Active power P, P1, P2, P3
Measurement Accuracy 1 % voltage 100...830 V) 3 % power factor 5 % active and reactive power
Overvoltage Category III
Connection Pitch 0.20 in (5.08 mm)
Connections - Terminals Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
Tightening Torque Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
Pollution Degree 3
Electromagnetic Compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) Conducted RF disturbances 10 V)EN/IEC 61000-4-6) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 4 kV)EN/IEC 61000-4-5)
Width 1.77 in (45 mm)
Height 2.40 in (61 mm)
Depth 4.75 in (120.7 mm)
Product Weight 0.46 lb(US) (0.21 kg)
Compatibility Code LTME
Standards IEC 60947-4-1 UL 508 EN 60947-4-1 IACS E10 CSA C22.2 No 14
Product Certifications UL NOM ATEX BV CSA EAC RINA LROS (Lloyds register of shipping) DNV ABS GL KERI RMRoS C-tick CCC
IP Degree Of Protection IP20
Protective Treatment 12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068
Fire Resistance 1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94
Ambient Air Temp For Op -4…140 °F (-20…60 °C)
Ambient Air Temp For Storage -40…176 °F (-40…80 °C)
Operating Altitude <= 6561.68 ft (2000 m) without derating
Mechanical Robustness Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6
Category 22338 - SOLID STATE OVERLOAD RELAYS
Discount Schedule I12
GTIN 00785901502395
Nbr. Of Units In Pkg. 1
Country Of Origin CN
Green Premium Status Green Premium product
EU RoHs Directive Compliant
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pvc Free Yes
Halogen Content Performance Halogen free plastic parts product
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by