| Part Number | LTMR08EBD |
|---|---|
| Country of Origin | CN |
| UPC | 785901552598 |
| UPC11 | 78590155259 |
| EAN | 3389119404860 |
| Availability | S |
| Lead Time | 33 |
| UNSPSC | 39122214 |
| HTs Code | 8537109160 |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 4.82 inch |
| Height | 2.40 inch |
| Width | 3.58 inch |
| Weight | 1.17 pound |
| Range | TeSys |
|---|---|
| Product Name | TeSys T |
| Device Short Name | LTMR |
| Product Or Component Type | Motor controller |
| Device Application | Equipment monitoring and control |
| Measurement Current | 0.4…8 A |
| [Us] Rated Supply Voltage | 24 V DC |
| Current Consumption | 56...127 mA |
| Supply Voltage Limits | 20.4…26.24 V DC |
| Communication Port Protocol | Modbus TCP/EtherNet/IP |
| Bus Type | Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs |
| Ui Rated Insulation Voltage | 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 |
| Uimp Rated Imp Wstd Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
| Short-Circuit Withstand | 100 kA EN/IEC 60947-4-1 |
| Associated Fuse Rating | 4 A gG output 0.5 A gG control circuit |
| Protection Type | Phase failure Locked rotor Earth-leakage protection Thermal protection Overload Phase unbalance Reverse polarity protection Power factor variation Overload (long time) Thermal overload protection Load fluctuation |
| Ntw And Machine Diagnosis Type | Event recording Remaining operating time before overload tripping Trip context information Waiting time after overload tripping Running hours counter/operating time Trip history information Fault recording Starting current and time Phase fault and earth fault trip counters Motor control command recording |
| Logic Input Number | 6 |
| Input Current | 7 mA |
| Current State 0 Guaranteed | Logic input < 5 V <= 15 mA 5 ms |
| Current State 1 Guaranteed | Logic input < 15 V 2...15 mA 15 ms |
| Maximum Output Switching Frequency | 2 Hz |
| Load Current | 5 A 250 V AC logic output 5 A 30 V DC logic output |
| Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Operating Rate | 1800 cyc/h |
| Contacts Type And Composition | 1 NO + 1 NC fault signal 3 NO |
| Metering Type | Average current Iavg Temperature Earth-fault current Phase current I1, I2, I3 RMS Imbalance current |
| Measurement Accuracy | 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power |
| Overvoltage Category | III |
| Connection Pitch | 0.20 in (5.08 mm) |
| Connections - Terminals | Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end |
| Tightening Torque | Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm) |
| Pollution Degree | 3 |
| Electromagnetic Compatibility | Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11) Conducted RF disturbances 10 V)EN/IEC 61000-4-6) Surges 0.5 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 4 kV)EN/IEC 61000-4-5) |
| Width | 3.58 in (91 mm) |
| Height | 2.40 in (61 mm) |
| Depth | 4.82 in (122.5 mm) |
| Product Weight | 1.17 lb(US) (0.53 kg) |
| Web Services | Web server |
| Compatibility Code | LTMR |
| Standards | IACS E10 UL 508 CSA C22.2 No 14 EN 60947-4-1 IEC 60947-4-1 |
| Product Certifications | CCC ABS C-tick NOM CSA RMRoS RINA UL BV KERI DNV GL EAC LROS (Lloyds register of shipping) ATEX |
| Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068 |
| Fire Resistance | 1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94 |
| Ambient Air Temp For Op | -4…140 °F (-20…60 °C) |
| Ambient Air Temp For Storage | -40…176 °F (-40…80 °C) |
| Operating Altitude | <= 6561.68 ft (2000 m) without derating |
| Mechanical Robustness | Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
| IP Degree Of Protection | IP20 |
| Category | 22338 - SOLID STATE OVERLOAD RELAYS |