Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Module XPSAR – Emergency stop – 230 V AC
XPSAR371144
Module XPSAR – Emergency stop – 230 V AC

This XPSAR safety module monitors emergency shutdown pushbuttons, limit switches and light curtains. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 and electrical monitoring of switches activated by protection devices conforming to standard EN/ISO 14119. And for monitoring of type 4 light curtains conforming to EN/IEC 61496-1 that have solid-state safety outputs with test function (light curtains XUS L). It is compatible with emergency push buttons, limit switches and safety light curtains, the 3 most common safety sensors in the industry. It has additional solid-state output for communication with PLCs about safety status of your process.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XPSAR371144
Country of Origin ID
UPC 785901601944
UPC11 78590160194
EAN 3389110274295
Availability N
Lead Time 43
UNSPSC 32151802
ECCN EAR99
HTs Code 8536490075
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule SAF2
Return Indicator No
Weight 0.88 pound
Characteristics
Range Of Product Preventa Safety automation
Product Or Component Type Preventa safety module
Safety Module Name XPSAR
Safety Module Application For emergency stop, switch and safety light curtain monitoring
Function Of Module Multiple emergency stop monitoring 2-channel wiring Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of a movable guard Emergency stop monitoring 1-channel wiring Monitoring of electro-sensitive protection equipment (ESPE) Emergency stop with 2 NC contacts monitoring 2-channel wiring
Safety Level Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061
Safety Reliability Data DC > 99 % EN/ISO 13849-1 MTTFd = 277.8 years EN/ISO 13849-1 PFHd = 2.22E-9 1/h EN/IEC 62061
Type Of Start Configurable
Connections - Terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output Type Relay instantaneous opening, 7 NO, volt-free
Number Of Additional Circuits 2 NC + 4 solid state outputs
Us Rated Supply Voltage 230 V AC - 15...10 % 24 V DC - 15...10 %
Synchro Time Between Inputs 100 ms
Supply Frequency 50/60 Hz
Power Consumption In W 4 W DC
Power Consumption In Va 9 VA AC
Input Protection Type Internal, electronic
Uc Control Circuit Voltage 24 V DC
Line Resistance 50 Ohm
Breaking Capacity 360 VA holding AC-15 C300 relay output 3600 VA inrush AC-15 C300 relay output
Breaking Capacity 20 mA 24 V 2 A 24 V DC-13)50 ms relay output
Output Thermal Current 10 A per relay relay output
Ith Cnvtl Free Air Therm Crrt 40 A
Associated Fuse Rating 10 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum Output Current 170 mA relay output
Minimum Output Voltage 17 V relay output
Response Time On Input Open 20 ms
Ui Rated Insulation Voltage 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1
Uimp Rated Imp Wstd Voltage 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1
Local Signalling 4 LEDs
Current Consumption 20 mA 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.88 lb(US) (0.4 kg)
Standards EN 1088/ISO 14119 EN/IEC 60947-5-1 EN/ISO 13850 EN/IEC 60204-1
Product Certifications TÜV UL CSA
IP Degree Of Protection IP20 terminals)EN/IEC 60529 IP40 enclosure)EN/IEC 60529
Ambient Air Temp For Op 14…131 °F (-10…55 °C)
Ambient Air Temp For Storage -13…185 °F (-25…85 °C)
Category 22477 - SAFETY MODULES (PREVENTA)
Discount Schedule SAF2
GTIN 00785901601944
Nbr. Of Units In Pkg. 1
Country Of Origin ID
Green Premium Status Green Premium product
EU RoHs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pvc Free Yes
Warranty 18 months