This XPSAR safety module monitors emergency shutdown pushbuttons, limit switches and light curtains. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 and electrical monitoring of switches activated by protection devices conforming to standard EN/ISO 14119. And for monitoring of type 4 light curtains conforming to EN/IEC 61496-1 that have solid-state safety outputs with test function (light curtains XUS L). It is compatible with emergency push buttons, limit switches and safety light curtains, the 3 most common safety sensors in the industry. It has additional solid-state output for communication with PLCs about safety status of your process.
Brand: Telemecanique
Add to Quote Catalogue| Part Number | XPSAR371144 |
|---|---|
| Country of Origin | ID |
| UPC | 785901601944 |
| UPC11 | 78590160194 |
| EAN | 3389110274295 |
| Availability | N |
| Lead Time | 43 |
| UNSPSC | 32151802 |
| ECCN | EAR99 |
| HTs Code | 8536490075 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | SAF2 |
| Return Indicator | No |
| Weight | 0.88 pound |
| Range Of Product | Preventa Safety automation |
|---|---|
| Product Or Component Type | Preventa safety module |
| Safety Module Name | XPSAR |
| Safety Module Application | For emergency stop, switch and safety light curtain monitoring |
| Function Of Module | Multiple emergency stop monitoring 2-channel wiring Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of a movable guard Emergency stop monitoring 1-channel wiring Monitoring of electro-sensitive protection equipment (ESPE) Emergency stop with 2 NC contacts monitoring 2-channel wiring |
| Safety Level | Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 |
| Safety Reliability Data | DC > 99 % EN/ISO 13849-1 MTTFd = 277.8 years EN/ISO 13849-1 PFHd = 2.22E-9 1/h EN/IEC 62061 |
| Type Of Start | Configurable |
| Connections - Terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output Type | Relay instantaneous opening, 7 NO, volt-free |
| Number Of Additional Circuits | 2 NC + 4 solid state outputs |
| Us Rated Supply Voltage | 230 V AC - 15...10 % 24 V DC - 15...10 % |
| Synchro Time Between Inputs | 100 ms |
| Supply Frequency | 50/60 Hz |
| Power Consumption In W | 4 W DC |
| Power Consumption In Va | 9 VA AC |
| Input Protection Type | Internal, electronic |
| Uc Control Circuit Voltage | 24 V DC |
| Line Resistance | 50 Ohm |
| Breaking Capacity | 360 VA holding AC-15 C300 relay output 3600 VA inrush AC-15 C300 relay output |
| Breaking Capacity | 20 mA 24 V 2 A 24 V DC-13)50 ms relay output |
| Output Thermal Current | 10 A per relay relay output |
| Ith Cnvtl Free Air Therm Crrt | 40 A |
| Associated Fuse Rating | 10 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum Output Current | 170 mA relay output |
| Minimum Output Voltage | 17 V relay output |
| Response Time On Input Open | 20 ms |
| Ui Rated Insulation Voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| Uimp Rated Imp Wstd Voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local Signalling | 4 LEDs |
| Current Consumption | 20 mA 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.88 lb(US) (0.4 kg) |
| Standards | EN 1088/ISO 14119 EN/IEC 60947-5-1 EN/ISO 13850 EN/IEC 60204-1 |
| Product Certifications | TÜV UL CSA |
| IP Degree Of Protection | IP20 terminals)EN/IEC 60529 IP40 enclosure)EN/IEC 60529 |
| Ambient Air Temp For Op | 14…131 °F (-10…55 °C) |
| Ambient Air Temp For Storage | -13…185 °F (-25…85 °C) |
| Category | 22477 - SAFETY MODULES (PREVENTA) |
| Discount Schedule | SAF2 |
| GTIN | 00785901601944 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | ID |
| Green Premium Status | Green Premium product |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Pvc Free | Yes |
| Warranty | 18 months |