This XPSABV safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 (instantaneous safety outputs), PL d/Category 3 (time delayed safety outputs) conforming to EN/ISO 13849-1. It meets also the requirements of SILCL3 (instantaneous safety outputs) and SILCL2 (time delayed safety outputs) conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring Emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 standards, and electrical monitoring of switches in protection devices conforming to EN/ISO 14119 standard. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.
Brand: Telemecanique
Add to Quote CataloguePart Number | XPSABV1133P |
---|---|
Country of Origin | DE |
UPC | 785901452430 |
UPC11 | 78590145243 |
EAN | 3389118376076 |
Availability | N |
Lead Time | 30 |
UNSPSC | 32151802 |
ECCN | EAR99 |
HTs Code | 8536410050 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | SAF2 |
Return Indicator | No |
Weight | 0.62 pound |
Range Of Product | Preventa Safety automation |
---|---|
Product Or Component Type | Preventa safety module |
Safety Module Name | XPSABV |
Safety Module Application | For emergency stop and switch monitoring |
Safety Level | Can reach PL d/category 3 time delay safety outputs EN/ISO 13849-1 Can reach PL e/category 4 instantaneous safety outputs EN/ISO 13849-1 Can reach SILCL 3 instantaneous safety outputs EN/IEC 62061 Can reach SILCL 2 time delay safety outputs EN/IEC 62061 |
Safety Reliability Data | MTTFd = 53 years instantaneous safety outputs EN/ISO 13849-1 MTTFd = 53 years time delay safety outputs EN/ISO 13849-1 DC > 99 % instantaneous safety outputs EN/ISO 13849-1 DC = 60...90 % time delay safety outputs EN/ISO 13849-1 PFHd = 3E-8 1/h instantaneous safety outputs EN/IEC 62061 PFHd = 2E-7 1/h time delay safety outputs EN/IEC 62061 |
Connections - Terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel |
Output Type | Relay instantaneous opening, 2 NO, volt-free Relay time delay opening, 1 NO, volt-free |
Us Rated Supply Voltage | 24 V DC - 15...10 % |
Synchro Time Between Inputs | < 0.5 s |
Power Consumption In W | 3 W DC |
Input Protection Type | Internal, electronic |
Time Delay Range | 1.5...30 s 0.15...3 s |
Uc Control Circuit Voltage | 24 V DC |
Breaking Capacity | 3600 VA inrush AC-15 B300 360 VA holding AC-15 B300 |
Breaking Capacity | 1.5 A 24 V DC-13)50 ms relay output |
Output Thermal Current | 6 A instantaneous and time delay outputs |
Ith Cnvtl Free Air Therm Crrt | 12 A |
Associated Fuse Rating | 6 A gG instantaneous and time delay outputs EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Minimum Output Current | 10 mA relay output |
Minimum Output Voltage | 17 V relay output |
Response Time On Input Open | 200 ms |
Ui Rated Insulation Voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
Uimp Rated Imp Wstd Voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
Local Signalling | 3 LEDs |
Mounting Support | 35 mm symmetrical DIN rail |
Product Weight | 0.62 lb(US) (0.28 kg) |
Standards | EN/IEC 60204-1 EN 1088/ISO 14119 EN/ISO 13850 EN/IEC 60947-5-1 |
Product Certifications | BG CSA UL |
IP Degree Of Protection | IP20EN/IEC 60529 IP40EN/IEC 60529 |
Ambient Air Temp For Op | -13…131 °F (-25…55 °C) |
Ambient Air Temp For Storage | -13…167 °F (-25…75 °C) |
Category | 22477 - SAFETY MODULES (PREVENTA) |
Discount Schedule | SAF2 |
GTIN | 00785901452430 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | DE |
Green Premium Status | Green Premium product |
REACh Free Of SVHC | Yes |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Toxic Heavy Metal Free | Yes |