This XPSABV safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 (instantaneous safety outputs), PL d/Category 3 (time delayed safety outputs) conforming to EN/ISO 13849-1. It meets also the requirements of SILCL3 (instantaneous safety outputs) and SILCL2 (time delayed safety outputs) conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring Emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 standards, and electrical monitoring of switches in protection devices conforming to EN/ISO 14119 standard. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.
Brand: Telemecanique
Add to Quote Catalogue| Part Number | XPSABV11330P |
|---|---|
| Country of Origin | DE |
| UPC | 785901069201 |
| UPC11 | 78590106920 |
| EAN | 3389118376083 |
| Availability | N |
| Lead Time | 30 |
| UNSPSC | 32151802 |
| ECCN | EAR99 |
| HTs Code | 8536410050 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | SAF2 |
| Return Indicator | No |
| Weight | 0.62 pound |
| Range Of Product | Preventa Safety automation |
|---|---|
| Product Or Component Type | Preventa safety module |
| Safety Module Name | XPSABV |
| Safety Module Application | For emergency stop and switch monitoring |
| Safety Level | Can reach PL d/category 3 time delay safety outputs EN/ISO 13849-1 Can reach PL e/category 4 instantaneous safety outputs EN/ISO 13849-1 Can reach SILCL 3 instantaneous safety outputs EN/IEC 62061 Can reach SILCL 2 time delay safety outputs EN/IEC 62061 |
| Safety Reliability Data | MTTFd = 53 years instantaneous safety outputs EN/ISO 13849-1 MTTFd = 53 years time delay safety outputs EN/ISO 13849-1 DC > 99 % instantaneous safety outputs EN/ISO 13849-1 DC = 60...90 % time delay safety outputs EN/ISO 13849-1 PFHd = 3E-8 1/h instantaneous safety outputs EN/IEC 62061 PFHd = 2E-7 1/h time delay safety outputs EN/IEC 62061 |
| Connections - Terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel |
| Output Type | Relay instantaneous opening, 2 NO, volt-free Relay time delay opening, 1 NO, volt-free |
| Us Rated Supply Voltage | 24 V DC - 15...10 % |
| Synchro Time Between Inputs | < 0.5 s |
| Power Consumption In W | 3 W |
| Input Protection Type | Internal, electronic |
| Time Delay Range | 0.15...3 s 1.5...30 s |
| Uc Control Circuit Voltage | 24 V DC |
| Breaking Capacity | 3600 VA inrush AC-15 B300 360 VA holding AC-15 B300 |
| Breaking Capacity | 1.5 A 24 V DC-13)50 ms relay output |
| Output Thermal Current | 6 A instantaneous and time delay outputs |
| Ith Cnvtl Free Air Therm Crrt | 12 A |
| Associated Fuse Rating | 6 A gG instantaneous and time delay outputs |
| Minimum Output Current | 10 mA relay output |
| Minimum Output Voltage | 17 V relay output |
| Response Time On Input Open | 200 ms |
| Ui Rated Insulation Voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| Uimp Rated Imp Wstd Voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local Signalling | 3 LEDs |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.62 lb(US) (0.28 kg) |
| Standards | EN/IEC 60947-5-1 EN 1088/ISO 14119 EN/ISO 13850 EN/IEC 60204-1 |
| Product Certifications | UL BG CSA |
| IP Degree Of Protection | IP20EN/IEC 60529 IP40EN/IEC 60529 |
| Ambient Air Temp For Op | -13…131 °F (-25…55 °C) |
| Ambient Air Temp For Storage | -13…167 °F (-25…75 °C) |
| Category | 22477 - SAFETY MODULES (PREVENTA) |
| Discount Schedule | SAF2 |
| GTIN | 00785901069201 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | DE |
| Green Premium Status | Green Premium product |
| REACh Free Of SVHC | Yes |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Pvc Free | Yes |
| Warranty | 18 months |
Powered by ![]()