Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Modular liquid level control relay, 8 A, 1 CO, 380…415 V AC/DC
RM22LG11MT
Modular liquid level control relay, 8 A, 1 CO, 380…415 V AC/DC

This Zelio RM22-LG relay allows monitoring of liquid level control in 3-phase networks. This modular multi function 3-phase liquid level control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.

Add to Quote Catalogue
Specifications
Part Number RM22LG11MT
Country of Origin ID
UPC 785901481164
UPC11 78590148116
EAN 3606480792335
Availability N
Lead Time 43
UNSPSC 39122329
ECCN EAR99
HTs Code 8536490080
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CP2
Return Indicator No
Width 0.89 inch
Weight 0.22 pound
Characteristics
Range Of Product Zelio Control
Product Or Component Type Modular measurement and control relays
Relay Type Level control relay
Relay Name RM22L
Relay Monitored Parameters Detection by resistive probes
Time Delay Type Without
Switching Capacity In Va 2000 VA
Measurement Range 5...100 kOhm
Reset Time 1750 ms
Maximum Switching Voltage 250 V AC
Minimum Switching Current 10 mA 5 V DC
Maximum Switching Current 8 A AC
[Us] Rated Supply Voltage 380...415 V AC 50/60 Hz
Supply Voltage Limits 323…456.5 V AC
Operating Limits 15 % + 10 % Un
Power Consumption In Va 8 VA AC
Output Contacts 2 C/O
Nominal Output Current 8 A
Run-Up Delay At Power-Up 0.6 s
Maximum Electrode Voltage 12 V AC
Maximum Electrode Current 1 mA
Repeat Accuracy +/- 2 % time delay
Measurement Error < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation
Sensitivity Scale 5...100 kOhm St (Standard Sensitivity)
Sensitivity Adjustment 5…100 %
Supply Current For Sensors 1 mA
Cable Distance Between Devices 3280.84 ft (1000 m) probe and delay
Cable Capacitance 1 nF HS (High Sensitivity) probe cable 2.2 nF St (Standard Sensitivity) probe cable 4.7 nF LS (Low Sensitivity) probe cable
Overvoltage Category III IEC 60664-1
Insulation Resistance > 100 MOhm 500 V DC IEC 60255-27
Insulation Between supply and measurement
Mounting Position Any position
Connections - Terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Tightening Torque 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
Housing Material Self-extinguishing plastic
Status Led Relay ON LED Yellow) Power ON LED Green)
Mounting Support 35 mm DIN rail EN/IEC 60715
Electrical Durability 100000 cycles
Mechanical Durability 10000000 cycles
Utilisation Category AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1
Safety Reliability Data MTTFd = 125.5 years B10d = 120000
Contacts Material Cadmium free
Width 0.89 in (22.5 mm)
Product Weight 0.22 lb(US) (0.1 kg)
Immunity To Microbreaks 100 ms DC 90 ms AC
Electromagnetic Compatibility Immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 Immunity for industrial environments EN/IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Emission standard for industrial environments EN/IEC 61000-6-4 Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 Surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 Surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 Conducted and radiated emissionsclass B group 1 CISPR 11 Conducted and radiated emissionsclass B CISPR 22
Standards EN/IEC 60255-1
Product Certifications CSA GL RCM UL China RoHS EAC CE CCC
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Ambient Air Temp For Op -4…122 °F (-20…50 °C) 60 Hz -4…140 °F (-20…60 °C) 50 Hz AC/DC
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews