This Zelio RM35-LM relay allows monitoring of level control in 3-phase networks. This modular multi function 3-phase liquid level control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
Add to Quote Catalogue| Part Number | RM35LM33MW |
|---|---|
| Country of Origin | ID |
| UPC | 785901565796 |
| UPC11 | 78590156579 |
| EAN | 3389119405232 |
| Availability | S |
| Lead Time | 48 |
| UNSPSC | 39122331 |
| ECCN | EAR99 |
| HTs Code | 8536490075 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | CP2 |
| Return Indicator | Yes |
| Width | 1.38 inch |
| Range Of Product | Zelio Control |
|---|---|
| Product Or Component Type | Modular measurement and control relays |
| Relay Type | Level control relay |
| Relay Name | RM35L |
| Relay Monitored Parameters | Detection by resistive probes |
| Time Delay | Adjustable 0.1...5 s, +/- 10 % |
| Switching Capacity In Va | 1250 VA |
| Minimum Switching Current | 10 mA 5 V DC |
| Maximum Switching Current | 5 A AC/DC |
| Power Consumption | 5 VA AC |
| Measurement Range | 250 Ohm...1 MOhm |
| Utilisation Category | AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 |
| Reset Time | 1750 ms |
| Maximum Switching Voltage | 250 V AC/DC |
| [Un] Rated Nominal Voltage | 24...240 V AC/DC 50/60 Hz +/- 10 % |
| Supply Voltage Limits | 20.4…264 V AC/DC |
| Operating Voltage Tolerance | 15 % + 10 % Un |
| Power Consumption | 1.5 W DC |
| Output Contacts | 2 C/O |
| Nominal Output Current | 5 A |
| Delay At Power Up | 0.6 s |
| Measurement Accuracy | +/- 10 % of the full scale value +/- 20 % for the HS range |
| Repeat Accuracy | +/- 2 % time delay |
| Measurement Error | 0.5 %/°C with temperature variation |
| Cable Distance Between Devices | 328.08 ft (100 m) |
| Sensitivity Scale | 0.25...5 kOhm LS (Low Sensitivity) 5...100 kOhm St (Standard Sensitivity) 50...1000 kOhm HS (High Sensitivity) |
| Sensitivity Adjustment | 5…100 % |
| Supply Current For Sensors | 1 mA |
| Cable Capacitance | 1 nF HS (High Sensitivity) probe cable 2.2 nF St (Standard Sensitivity) probe cable 4.7 nF LS (Low Sensitivity) |
| Marking | CE : 73/23/EEC CE : EMC 89/336/EEC |
| Overvoltage Category | III IEC 60664-1 |
| Insulation Resistance | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5 > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 > 1 MOhm 500 V DC between supply and measurement IEC 60664-1 |
| Ui Rated Insulation Voltage | 250 V IEC 60664-1 |
| Operating Position | Any position without derating |
| Connections - Terminals | Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end |
| Tightening Torque | 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1 |
| Housing Material | Self-extinguishing plastic |
| Local Signalling | Relay ON LED yellow) Power ON LED green) Timer ON LED yellow) |
| Mounting Support | 35 mm symmetrical DIN rail EN/IEC 60715 |
| Electrical Durability | 100000 cycles |
| Mechanical Durability | 30000000 cycles |
| Operating Rate | <= 360 operations/hour full load |
| Safety Reliability Data | B10d = 170000 MTTFd = 182.6 years |
| Width | 1.38 in (35 mm) |
| Immunity To Microbreaks | 100 ms DC 90 ms AC |
| Electromagnetic Compatibility | Emission standard for industrial environments EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2 |
| Standards | EN/IEC 60255-6 |
| Product Certifications | CSA GL UL C-tick GOST |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Ambient Air Temp For Op | -4…122 °F (-20…50 °C) |