Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Modular 1-phase voltage control relay, 8 A, 2 CO, 80…300 V AC/DC, 110…240 V AC/DC
RM22UB34
Modular 1-phase voltage control relay, 8 A, 2 CO, 80…300 V AC/DC, 110…240 V AC/DC

This Zelio RM22-UB relay allows monitoring of voltage control in single phase networks. This modular multi function single phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.

Add to Quote Catalogue
Specifications
Part Number RM22UB34
Country of Origin ID
UPC 785901472025
UPC11 78590147202
EAN 3606480792274
Availability N
Lead Time 15
UNSPSC 39122329
HTs Code 8536490080
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CP2
Return Indicator Yes
Width 0.89 inch
Weight 0.20 pound
Characteristics
Range Of Product Zelio Control
Product Or Component Type Modular measurement and control relays
Relay Type Voltage control relay
Network Number Of Phases 1 phase
Supply Circuit Type DC
Relay Name RM22UA
Relay Monitored Parameters Overvoltage and undervoltage detection
Time Delay Type Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Switching Capacity In Va 2000 VA
Measurement Range 80...300 V voltage AC/DC 50/60 Hz
Reset Time 1500 ms at maximum voltage
Maximum Switching Voltage 250 V AC
Minimum Switching Current 10 mA 5 V DC
Maximum Switching Current 8 A AC
[Us] Rated Supply Voltage 110...240 V AC 50/60 Hz
Supply Voltage Limits 60…280 V AC
Power Consumption In Va 5 VA AC
Power Consumption In W 2 W DC
Supply Voltage Frequency 50...60 Hz +/- 10 %
Output Contacts 2 C/O
Nominal Output Current 8 A
Hysteresis 5…50 % adjustable threshold setting
Run-Up Delay At Power-Up 600 ms
Measuring Cycle 250 ms measurement cycle as true rms value
Repeat Accuracy +/- 0.5 % input and measurement circuit +/- 2 % time delay
Measurement Error < 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation
Response Time <= 500 ms
Overvoltage Category III IEC 60664-1
Insulation Resistance > 100 MOhm 500 V DC IEC 60255-27
Mounting Position Any position
Connections - Terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Tightening Torque 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
Housing Material Self-extinguishing plastic
Status Led Relay ON LED Yellow) Power ON LED Green)
Mounting Support 35 mm DIN rail EN/IEC 60715
Electrical Durability 100000 cycles
Mechanical Durability 10000000 cycles
Utilisation Category AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1
Safety Reliability Data MTTFd = 433.7 years B10d = 400000
Contacts Material Cadmium free
Width 0.89 in (22.5 mm)
Product Weight 0.20 lb(US) (0.09 kg)
Immunity To Microbreaks 20 ms
Electromagnetic Compatibility Immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 Immunity for industrial environments EN/IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Emission standard for industrial environments EN/IEC 61000-6-4 Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 Surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 Surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 Conducted and radiated emissionsclass B group 1 CISPR 11 Conducted and radiated emissionsclass B CISPR 22
Standards EN/IEC 60255-1
Product Certifications CCC China RoHS CE CSA EAC UL GL RCM
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Ambient Air Temp For Op -4…122 °F (-20…50 °C) 60 Hz -4…140 °F (-20…60 °C) 50 Hz AC/DC
Relative Humidity 93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30
Vibration Resistance 0.075 mm 10…58.1 Hz) not in operation IEC 60068-2-6 1 gn 10…58.1 Hz) not in operation IEC 60068-2-6 0.035 mm 58.1…150 Hz) in operation IEC 60068-2-6 0.5 gn 58.1…150 Hz) in operation IEC 60068-2-6