Part Number | BMKC8030311 |
---|---|
UPC | 606485445168 |
UPC11 | 60648544516 |
EAN | 3606485445168 |
Availability | N |
Lead Time | 63 |
ECCN | EAR99 |
HTs Code | 8537109170 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | PC34 |
Range Of Product | Modicon MC80 |
---|---|
Product Or Component Type | Processor module |
Product Specific Application | Thermo solar - tower power |
Product Compatibility | BMXFTB28... terminal block high-speed counter module BMXFTB20... terminal block analog input module BMXFTB28... terminal block discrete I/O module |
[Us] Rated Supply Voltage | 24 V - 15...20 % DC |
Current Consumption | <= 700 mA |
ISOlation Voltage | 1500 V DC |
Memory Description | Internal RAM 3840 kB Internal RAM 128 kB data Internal RAM 3590 kB program constants and symbols |
Execution Time Per Instruction | 0.06 µs Boolean 0.08 µs mixed |
Realtime Clock | With |
Function Available | Memory retention without battery |
Communication Port Protocol | 1 non isolated serial link RJ45 RS485/RS232 0.3...19.2 kbit/s 247 1 CANopen SUB-D 9 20 kbit/s...1 Mbit/s 16 2 Ethernet RJ45 10/100 Mbit/s |
Integrated Connection Type | USB port mini B USB |
Port Ethernet | 10BASE-T/100BASE-TX |
Bus Length | 0.00…32.81 ft (0…10 m) serial link non isolated 0.00…49.21 ft (0…15 m) serial link non isolated 0.00…3280.84 ft (0…1000 m) serial link isolated with external isolation tap 0.00…65.62 ft (0…20 m) 1 Mbit/s CANopen 0.00…8202.10 ft (0…2500 m) 20 kbit/s CANopen 0.00…328.08 ft (0…100 m) Ethernet |
Communication Service | Read/write variables Modbus Diagnostics Modbus Send/receive character string character mode Process Data Object (PDO) CANopen Service Data Object (SDO) CANopen FDR client Ethernet SNMP Ethernet RSTP support Ethernet |
Number Of Counter | 2 |
Counting Frequency | 60000 Hz |
Counter Functions | Count events Frequency meter Ratio count One shot counting Measure time periods Freelarge counting Loop (modulo) counting |
Number Of Inputs For Counter | 3 auxiliary 3 high speed |
Logic Input For Counter | Positive (sink) |
Sensor Power Supply For Counter | 19…30 V DC |
Input Compatibility For Counter | 24 V 2-wire/3-wire proximity sensor incremental encoder with push-pull outputs, 10...30 V totem pole 24 V 2/3-wire sensor PNP |
Number Of Outputs For Counter | 2 positive |
Nominal Output Current For Counter | 0.5 A per output |
Discrete Input Number | 8 positive logic (sink) |
Discrete Input Type | Type 3 |
Discrete Input Current | 2.4 mA |
Discrete Input Voltage | 19...30 V DC |
Discrete Output Number | 12 positive |
Discrete Output Current | 2 A per output 10 A per module |
Discrete Output Voltage | 19...30 V DC |
Protection Type | Overload protection output Short-circuit protection output |
Analogue Input Number | 4 |
Analogue Input Type | Current - 20...20 mA Voltage - 10...10 V |
Fast Read Cycle Time For Analogue Input | 1.3 ms + 1.3 ms x number of channels used |
Nominal Read Cycle Time For Analogue Input | 6.5 ms for 4 channels |
Analogue Input Resolution | 16 bits |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Relative Humidity | 0…95 % |
Vibration Resistance | 3 gn |
Marking | CE |
Standards | UL 508 CSA C22.2 No 213 Class I Division 2 Group C CSA C22.2 No 142 IEC 61131-2 CSA C22.2 No 213 Class I Division 2 Group A CSA C22.2 No 213 Class I Division 2 Group D CSA C22.2 No 213 Class I Division 2 Group B |
Product Certifications | RCM |
GTIN | 03606485445168 |
Green Premium Status | Green Premium product |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366