| Part Number | GWTUPS200 |
|---|---|
| Depth | 32.48 inch |
| Height | 74.80 inch |
| Width | 39.96 inch |
| Weight | 2645.55 pound |
| Presentation | Performance 3 phase power protection designed for flexibility in order to meet a wide range of requirements: from data centers to industrial and facilities applications. |
|---|---|
| Lead Time | Usually Ships within 2 Weeks |
| Provided Equipment | Installation guide User Manual |
| Bypass Wiring Configuration | 4 wire (3PH + N) 5 wire (3PH + N + G) |
| Bypass Voltage Tolerance | +/-10% settable from +/-4/6/8 and 10% |
| Max Bypass Input Current | 338 A |
| Bypass Current Protection | 400 A |
| Colour | Beige |
| Depth | 32.48 in (82.5 cm) |
| Height | 74.80 in (190 cm) |
| Product Weight | 2645.55 lb(US) (1200 kg) |
| Width | 39.96 in (101.5 cm) |
| Network Frequency | 45...65 Hz |
| Number Of Input Connectors | 1 Hard Wire 4-wire (3PH + N) 1 Hard Wire 5-wire (3PH + N + G) |
| Input Voltage Limits | 323...437 V adjustable 380 V 340...460 V adjustable 400 V 357...477 V adjustable 415 V 177...239 V 208 V 340...460 V 400 V 408...552 V 480 V |
| Inputvolt_Other | 400 V |
| Maximum Input Current | 692 A |
| Switching Current Capacity | 400 A |
| Max Short Time Withstd Current | 16 kA |
| Input Harmonic Distortion | Less than 7% for full load |
| Input Protection Type | 3-pole breaker |
| Input Voltage | 3 phase 3 phase 3 phase |
| Rated Power In W | 160000 W |
| Max Configurable Power In W | 160000 W |
| Harmonic Distortion | Less than 2% |
| Output Frequency | 50/60 Hz +/- 5 % sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced 50 Hz +/- 0.1 % for 50 Hz nominal not synced |
| Outputvolt_Other | 400 V |
| Ups Type | Double Conversion Online |
| Wave Type | Sine wave |
| Output Connector Type | Hard Wire 5-wire (3PH + N + G) 1 Hard Wire 4-wire (3PH + N) 1 |
| Output Voltage Tolerance | +/-1% static and +/- 5% at 100% load step |
| Output Harmonic Distortion | < 2% linear load and < 3% non-linear load |
| Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
| Req Output Current Protection | 289 A |
| Neutral Output Current | 433 A |
| Bypass Type | Built-in Maintenance Bypass |
| Output Voltage | 208 V 3 phase 480 V 3 phase 600 V 3 phase |
| Product Certifications | CE LCIE TÜV |
| Standards | EN/IEC 62040-2 EN/IEC 62040-3 EN/IEC 62040-1-1 IEC 61000-4-5 ISO 14001 ISO 9001 |
| Ambient Air Temp For Op | 32…95 °F (0…35 °C) |
| Relative Humidity | 20…80 % |
| Operating Altitude | 0...3281 ft |
| Ambient Air Temp For Storage | -13…104 °F (-25…40 °C) |
| Storage Altitude | 0…30000 ft (0.00…9144.00 m) |
| Acoustic Level | 68 dBA |
| IP Degree Of Protection | IP20 |
| Battery Type | External battery system |
| Additional Information | Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366