Part Number | G55TUPM100HXS |
---|---|
UPC | 731304315490 |
UPC11 | 73130431549 |
EAN | 0731304315490 |
Depth | 33.66 inch |
Height | 85.83 inch |
Width | 28.03 inch |
Weight | 1225.77 pound |
Presentation | UPS is designed to meet the offshore standard requirement. |
---|---|
Lead Time | Special Order - Call for Quoted Lead Times |
Provided Equipment | Installation guide User Manual |
Bypass Wiring Configuration | 4 wire (3PH + N) 5 wire (3PH + N + G) |
Bypass Voltage Tolerance | +/-10% settable from +/-4/6/8 and 10% |
Max Bypass Input Current | 144 A |
Bypass Current Protection | 200 A |
Depth | 33.66 in (85.5 cm) |
Height | 85.83 in (218 cm) |
Product Weight | 1225.77 lb(US) (556 kg) |
Width | 28.03 in (71.2 cm) |
Network Frequency | 45...65 Hz |
Number Of Input Connectors | 1 Hard Wire 4-wire (3PH + G) 1 Hard Wire 4-wire (3PH + N) |
Input Voltage Limits | 323...437 V 380 V 340...460 V 400 V 353...477 V 415 V |
Inputvolt_Other | 380 V 400 V 415 V |
Maximum Input Current | 190 A |
Switching Current Capacity | 250 A |
Max Short Time Withstd Current | 30 kA |
Input Harmonic Distortion | Less than 3% for full load |
Input Protection Type | GL fuse |
Input Voltage | 3 phase |
Rated Power In W | 90000 W |
Max Configurable Power In W | 90000 W |
Harmonic Distortion | Less than 2% |
Output Frequency | 50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8% sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal not synced |
Outputvolt_Other | 380 V 415 V |
Crest Factor | 3 : 1 |
Ups Type | Double Conversion Online |
Wave Type | Sine wave |
Output Connector Type | Hard Wire 4-wire (3PH + G) 1 |
Output Voltage Tolerance | +/- 2% static and 100% load step |
Output Harmonic Distortion | < 1% linear load and < 2.5% non-linear load |
Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
Req Output Current Protection | 144 A |
Neutral Output Current | 217 A |
Bypass Type | Built-in Maintenance Bypass Built-in Static Bypass Optional External Bypass |
Output Voltage | 400 V 3 phase |
Product Certifications | CE TÜV VDE |
Standards | IEC 62040-1-2 EN/IEC 62040-2 EN/IEC 62040-3 ISO 9001 |
Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
Relative Humidity | 0…95 % |
Operating Altitude | 0...3333 ft |
Ambient Air Temp For Storage | -4…113 °F (-20…45 °C) |
Storage Altitude | 0…40000 ft (0.00…12192.00 m) |
Acoustic Level | 63 dBA |
IP Degree Of Protection | IP20 |
Battery Type | External battery system |
Additional Information | Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211