Specifications
Part Number G5TUPS40
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
Depth 33.39 inch
Height 74.80 inch
Width 28.03 inch
Weight 881.85 pound
Characteristics
Presentation A versatile 3-phase UPS for facility, industrial and data center applications. Configurable system with a comprehensive range of accessories to meet your application demands.
Lead Time Usually Ships within 2 Weeks
Provided Equipment Installation guide User Manual
Colour Charcoal
Depth 33.39 in (84.8 cm)
Height 74.80 in (190 cm)
Product Weight 881.85 lb(US) (400 kg)
Width 28.03 in (71.2 cm)
Network Frequency 45...65 Hz
Number Of Input Connectors 1 Hard Wire 4-wire (3PH + G)
Input Voltage Limits 340...460 V 400 V 408...538 V
Inputvolt_Other 380 V 400 V 415 V 480 V 600 V
Maximum Input Current 77 A
Switching Current Capacity 125 A
Max Short Time Withstd Current 20 kA
Input Harmonic Distortion Less than 3% for full load
Input Protection Type 3-pole breaker
Input Voltage 3 phase 3 phase 3 phase
Rated Power In W 36000 W
Max Configurable Power In W 36000 W
Harmonic Distortion Less than 2%
Output Frequency 50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8% sync to mains 60 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced 50 Hz +/- 0.1 % for 50 Hz nominal not synced
Outputvolt_Other 208 V 220 V 380 V 400 V 415 V 600 V
Crest Factor 3 : 1
Ups Type Double Conversion Online
Wave Type Sine wave
Output Connector Type Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Harmonic Distortion < 1% linear load and < 2.5% non-linear load
Output Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Neutral Output Current 87 A
Bypass Type Internal Bypass (Automatic and Manual) Optional External Bypass
Output Voltage 400 V 3 phase 480 V 3 phase 600 V 3 phase
Product Certifications CE TÜV VDE
Standards EN/IEC 62040-1-1 EN/IEC 62040-3 IEC 60950 IEC 61000-3-2 IEC 61000-3-3 EN 61000-4-5 IEC 62040-1-2 IEC 62040-2 ISO 9001
Ambient Air Temp For Op 32…104 °F (0…40 °C)
Relative Humidity 0…95 %
Operating Altitude 0...3333 ft
Ambient Air Temp For Storage -4…113 °F (-20…45 °C)
Storage Altitude 0…10000 ft (0.00…3048.00 m)
Acoustic Level 66 dBA
Heat Dissipation 8974 Btu/h
Battery Type External battery system
Additional Information Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Free Slots 3
Control Panel Multi-function LCD status and control console
Emergency Power Off Optional