Part Number | G35T15KF4B4S |
---|---|
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Depth | 32.99 inch |
Height | 58.70 inch |
Width | 20.59 inch |
Weight | 1320.79 pound |
Lead Time | Usually Ships within 2 Weeks |
---|---|
Provided Equipment | Battery modules ship installed Bolt down brackets CD with software Installation guide Network Management Card Power modules ship installed Smart UPS signalling RS-232 cable Start-Up Service User Manual |
Depth | 32.99 in (83.8 cm) |
Height | 58.70 in (149.1 cm) |
Product Weight | 1320.79 lb(US) (599.1 kg) |
Width | 20.59 in (52.3 cm) |
Network Frequency | 40 - 70 Hz auto-sensing |
Number Of Input Connectors | 1 Hard Wire 5-wire (3PH + N + G) |
Input Voltage Limits | 160...240 V |
Input Voltage | 3 phase |
Rated Power In W | 12000 W |
Max Configurable Power In W | 12000 W |
Output Frequency | 57...63 Hz for 60 Hz nominal sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced |
Crest Factor | Unlimited |
Ups Type | Double Conversion Online |
Wave Type | Sine wave |
Connections - Terminals | 1 screw terminals |
Output Connector Type | Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1 |
Output Voltage Tolerance | +/- 5% static and 100% load step |
Output Harmonic Distortion | < 2% linear load and < 4% non-linear load |
Bypass Type | Built-in Maintenance Bypass Built-in Static Bypass |
Output Voltage | 208 V 3 phase |
Product Certifications | CUL Listed CSA UL 1778 |
Standards | CSA C22.2 No. 107.1 ISO 14001 ISO 9001 |
Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
Relative Humidity | 0…95 % |
Operating Altitude | 0...3333 ft |
Ambient Air Temp For Storage | 5…113 °F (-15…45 °C) |
Storage Altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic Level | 51.3 dBA |
Heat Dissipation | 2989 Btu/h |
Nema Degree Of Protection | NEMA 12 |
IP Degree Of Protection | IP51 |
Battery Type | Lead-Acid battery |
Number Of Battery Filled Slots | 4 |
Battery Recharge Time | 5 h |
Number Of Battery Repl Qty | 4 |
Additional Information | Configurable for 200 : 208 or 220V 3 Phase nominal output voltage |
Battery Voltage | +/-192 V (split battery referenced to neutral) |
Discharge Battery Voltage | +/-154 V |
Preinstalled Device | Network management card 2 with environmental monitoring |
EU RoHs Directive | Under investigation |
Mercury Free | Yes |
Warranty | 1 year repair or replace |