Specifications
Part Number XCSB513
UPC 785901465638
UPC11 78590146563
EAN 3389110185157
UNSPSC 39122213
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
Return Indicator No
Depth 1.73 inch
Height 4.49 inch
Width 2.05 inch
Weight 1.05 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Safety switch
Component Name XCSB
Design Industrial
Material Metal
Head Type Key operated turret head
Contacts Type And Composition 1 NC + 2 NO
Contact Operation Slow-break, break before make
Cable Entry 1 entry tapped 1/2" NPT
Electrical Connection Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Number Of Poles 3
Locking Options Description With locking of actuator, unlocking by push-button
Local Signalling On opening of NC contacts 1 LED orange)
Signalling Circuit Voltage 24/48 V
Positive Opening With NC contact
Signalling Circuit Type AC/DC
Mechanical Durability 600000 cycles
Minimum Actuation Speed 0.03 ft/s (0.01 m/s)
Maximum Actuation Speed 1.64 ft/s (0.5 m/s)
Ie Rated Operational Current 6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Ithe Cnvtl Enclosed Therm Crrt 10 A
Ui Rated Insulation Voltage 300 VUL 508 500 VEN/IEC 60947-1 300 VCSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-5-1
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Actutr Forcible Withdrawal Rtc 1500 N
Actutr Force For Extractn 20 N
Operating Rate 10 cyc/mn for maximum durability
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body Material Zamak
Head Material Zamak
Depth 1.73 in (44 mm)
Height 4.49 in (114 mm)
Width 2.05 in (52 mm)
Product Weight 1.05 lb(US) (0.475 kg)
Standards EN/IEC 60204-1 EN/IEC 60947-5-1 EN 1088/ISO 14119 CSA C22.2 No 14 EN/ISO 12100 UL 508
Product Certifications CSA UL
Protective Treatment TC
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Vibration Resistance 5 gn 10…500 Hz)IEC 60068-2-6
Shock Resistance 10 gn 11 ms IEC 60068-2-27
Electrical Shock Protect Class Class I EN/IEC 61140
IP Degree Of Protection IP67 EN/IEC 60529 and EN/IEC 60947-5-1
Category 22411 - LIMIT SWITCHES,IEC,XCKJ
Discount Schedule T
GTIN 00785901465638
Nbr. Of Units In Pkg. 1
Country Of Origin FR
EU RoHs Directive Not applicable, out of EU RoHS legal scope
Documents