This XCSLF Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated slim Zamak body with a 19-pin M23 connector, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 2 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 500 000. Its IP65 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Add to Quote Catalogue| Part Number | XCSLF353531M3 |
|---|---|
| Country of Origin | ID |
| UPC | 606480465482 |
| UPC11 | 60648046548 |
| EAN | 3606480465482 |
| Availability | N |
| Lead Time | 28 |
| UNSPSC | 39122213 |
| ECCN | EAR99 |
| HTs Code | 8536509065 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | T |
| Return Indicator | No |
| Depth | 2.01 inch |
| Height | 8.86 inch |
| Width | 1.73 inch |
| Weight | 2.43 pound |
| Range Of Product | Preventa Safety detection |
|---|---|
| Product Or Component Type | Safety switch |
| Component Name | XCSLF |
| Design | Slim |
| Material | Metal |
| Head Type | Key operated turret head |
| Contacts Type And Composition | 1 NC + 2 NO |
| Contact Operation | Slow-break, break before make |
| Solenoid Contacts Type Compo | 1 NC + 2 NO slow-break, break before make) |
| Electromagnet Interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
| [Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage | 24 V - 15...10 % |
| Cable Outer Diameter | 0.28…0.51 in (7…13 mm) |
| Electrical Connection | Male connector M23, 19 pins |
| Number Of Poles | 3 |
| Locking Options Description | With interlocking, locking by solenoid |
| Local Signalling | Actuator withdrawn 1 LED orange) Actuator inserted and locked 1 LED green) |
| Signalling Circuit Voltage | 24 V |
| Positive Opening | With NC contact |
| Supply Voltage Type | AC/DC |
| Supply Frequency | 50/60 Hz |
| Load Factor | 1 |
| Signalling Circuit Type | AC/DC |
| Mechanical Durability | 1000000 cycles |
| Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
| Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
| Ie Rated Operational Current | 1.5 A 24 V, AC-15 EN/IEC 60947-5-1 0.22 A 24 V, DC-13 EN/IEC 60947-5-1 |
| Ithe Cnvtl Enclosed Therm Crrt | 4 A |
| Maximum Load Current | <= 15 A |
| Ui Rated Insulation Voltage | 60 V 3)EN/IEC 60947-1 50 VUL 508 50 VCSA C22.2 No 14 |
| Uimp Rated Imp Wstd Voltage | 0.8 kV EN/IEC 60947-5-1 |
| Minimum Switching Current | 10 mA at 20 °C |
| Minimum Switching Voltage | 17 V |
| Short-Circuit Protection | 4 A cartridge fuse gG (gl) 6 A fast blow |
| Acttr Forcible Wdrawal Rtc | 3000 N |
| Actutr Force For Extractn | 20 N |
| Rtc To Mechanical Impact | 9.6 J against the partition 6.4 J without partition |
| Operating Rate | 10 cyc/mn for maximum durability |
| Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 EN/IEC 61508 |
| Safety Reliability Data | B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear |
| Body Material | Zamak |
| Head Material | Zamak |
| Depth | 2.01 in (51 mm) |
| Height | 8.86 in (225 mm) |
| Width | 1.73 in (44 mm) |
| Product Weight | 2.43 lb(US) (1.1 kg) |
| Standards | UL 508 CSA C22.2 No 14 EN/IEC 60204-1 EN/IEC 60947-5-1 EN 1088/ISO 14119 EN/ISO 13849-1 EN/IEC 62061 |
| Product Certifications | CSA UL TÜV |
| Protective Treatment | TC |
| Ambient Air Temp For Op | -13…140 °F (-25…60 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |