Part Number | ATV6000C240A4242NA3 |
---|---|
UNSPSC | 26111503 |
Depth | 59.06 inch |
Height | 105.16 inch |
Width | 203.39 inch |
Weight | 19043.55 pound |
Range Of Product | Altivar Process ATV6000 |
---|---|
Product Or Component Type | Medium voltage variable speed drive |
Device Short Name | ATV6000 |
Product Specific Application | Process and utilities |
Assembly Style | In floor-standing enclosure |
Provided Equipment | Medium voltage arrestors Phase-shifting transformer Plinth Human machine interface Enclosure Power cells Cooling fans |
Colour Of Enclosure | Light grey RAL 7035) |
IP Degree Of Protection | IP31 IEC 60529 |
Type Of Cooling | Forced convection |
Input Type | 24 pulse diode rectifier bridge |
Output Type | IGBT inverter cells multilevel PWM |
[Us] Rated Supply Voltage | 4.16 kV +/- 10 % |
Supply Frequency | 50 Hz +/- 5 % |
Network Number Of Phases | 3 phase |
Prospective Line Isc | 31.5 kA 150 ms |
Output Voltage | <= power supply voltage |
Perm Temporary Current Boost | 1.2 x In 60 s normal duty) 1.5 x In 3 s normal duty) 1.5 x In 60 s heavy duty) 1.8 x In 3 s heavy duty) |
Speed Drive Output Frequency | 0.5…120 Hz |
Frequency Resolution | 0.01 Hz |
Product Destination | Permanent magnet motors Synchronous motors Asynchronous motors |
Async Motor Control Profile | Constant torque standard Sensorless flux vector control Variable torque standard Closed loop vector control Dynamic energy saving |
Sync Motor Control Profile | Vector control Permanent magnet motor Synchronous motor with external exitation |
Apparent Power | 2400 kVA |
Thdi | <3 % IEEE 519-1992 |
Power Factor | 96 |
Motor Power kW | 1920 kW normal duty 1540 kW heavy duty |
Continuous Output Current | 320 A normal duty 256 A heavy duty |
Max Transient Current | 480 A 3 s normal duty) 480 A 3 s heavy duty) |
Line Current | 333 A normal duty 267 A heavy duty |
Energy Efficiency Ratio | 0.98 inverter 0.961 total drive including transformer |
Power Losses | 81.7 kW normal duty 65.4 kW heavy duty |
Cable Entry | Bottom |
Electrical Connection | M10 bar main supply M10 bar motor Terminal 0.25...2.5 mm² control Terminal 1.5...16 mm² cooling fan |
Cable Cross Section | 0.11 in² (70 mm²) line heavy duty 0.11 in² (70 mm²) motor heavy duty 0.19 in² (120 mm²) line normal duty 0.19 in² (120 mm²) motor normal duty |
Width | 203.39 in (5166 mm) |
Depth | 59.06 in (1500 mm) |
Height | 105.16 in (2671 mm) |
Product Weight | 19043.55 lb(US) (8638 kg) |
Volume Of Cooling Air | 4949193.52 Gal/hr(US) (18734.4 m3/h) |
Noise Level | 80 dB |
Emc Filter | Integrated EN/IEC 61800-3 category C3 control Integrated EN/IEC 61800-3 category C4 Power |
Display Type | 10 inch LCD touch screen multi-language |
Protection Type | Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive |
Option Card | Slot A communication module Profibus DP V1 Slot A communication module Profinet Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module Slot B HTL encoder interface module Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module |
Connector Type | 2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial |
Communication Port Protocol | Ethernet IP/Modbus TCP |
Supply | Internal supply for digital inputs and PoE 24 V DC 21…27 V, <200 mA overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection External supply for digital inputs 24 V DC 19…30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA |
Analogue Input Type | configurable voltage 0...10 V DC 30 kOhm 12 bits configurable current 0...20 mA 250 Ohm 12 bits |
Discrete Input Number | 10 |
Discrete Input Type | DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V) POEA, POEB PWM output enable, 24 V DC <= 30 V)> 2.2 kOhm |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705