This XCKL classic format limit switch has a “cat’s whiskers” and a Zamak body. This limit switch has a robust Zamak body, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCKL106 |
---|---|
Country of Origin | FR |
UPC | 785901646518 |
UPC11 | 78590164651 |
EAN | 3389110646511 |
Availability | S |
Lead Time | 33 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509055 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | Yes |
Depth | 1.18 inch |
Height | 2.83 inch |
Width | 2.05 inch |
Weight | 0.56 pound |
Range Of Product | OsiSense XC |
---|---|
Series Name | Standard format |
Product Or Component Type | Limit switch |
Device Short Name | XCKL |
Body Type | Fixed |
Head Type | Multi-directional head |
Material | Metal |
Body Material | Zamak |
Fixing Mode | By the body |
Movement Of Operating Head | Multi-directional |
Type Of Operator | Spring return cat''s whisker |
Type Of Approach | Multi-directional approach |
Cable Entry | 1 metal cable gland entry 0.24…0.53 in (6…13.5 mm) |
Number Of Poles | 2 |
Contacts Type And Composition | 1 NC + 1 NO |
Contact Operation | Snap action |
Switch Actuation | By any moving part |
Electrical Connection | Screw-clamp terminals 1 x 0.34...2 x 1.5 mm² |
Contacts Insulation Form | Zb |
Number Of Steps | 1 |
Positive Opening | Without |
Minimum Torque For Tripping | 1.15 lbf.in (0.13 N.m) |
Minimum Actuation Speed | 0.01 m/min |
Maximum Actuation Speed | 3.28 ft/s (1 m/s) |
Contact Code Designation | A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A |
Ithe Cnvtl Enclosed Therm Crrt | 10 A AC |
Ui Rated Insulation Voltage | 300 VUL 508 500 V 3)IEC 60947-1 300 VCSA C22.2 No 14 |
Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60664 6 kV IEC 60947-1 |
Short-Circuit Protection | 10 A cartridge fuse gG |
Electrical Durability | 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
Mechanical Durability | 10000000 cycles |
Width | 2.05 in (52 mm) |
Height | 2.83 in (72 mm) |
Depth | 1.18 in (30 mm) |
Product Weight | 0.56 lb(US) (0.255 kg) |
Terminals Description ISO n°1 | (21-22)NC (13-14)NO |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 25 gn 10…500 Hz)EN/IEC 60068-2-6 |
IP Degree Of Protection | IP66 EN/IEC 60529 |
IK Degree Of Protection | IK05 EN 50102 |
Electrical Shock Protect Class | Class I IEC 61140 Class I NF C 20-030 |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Protective Treatment | TC |
Product Certifications | CSA UL |
Standards | IEC 60204-1 UL 508 IEC 60947-5-1 EN 60947-5-1 CSA C22.2 No 14 EN 60204-1 |
Category | 22416 - LIMIT SWITCHES,IEC,XCKL |
Discount Schedule | T |
GTIN | 00785901646518 |