This product is an industrial EN 50041 format limit switch with 1 Pg 13.5 cable entry. It features a metal fixed body and a rotary head, with a variable length thermoplastic roller lever. Contacts: 2-pole NC + NO, break before make, slow break. This limit switch is supplied for actuation from left and right. The XCKJ range offers the most robust heads in his category.
Brand: Telemecanique
Add to Quote Catalogue| Part Number | XCKJ50541 |
|---|---|
| Country of Origin | ID |
| UPC | 785901589013 |
| UPC11 | 78590158901 |
| EAN | 3389110646085 |
| Availability | N |
| UNSPSC | 39122213 |
| ECCN | EAR99 |
| HTs Code | 8536509055 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | T |
| Return Indicator | No |
| Depth | 1.73 inch |
| Height | 3.03 inch |
| Width | 1.57 inch |
| Weight | 1.07 pound |
| Range Of Product | OsiSense XC |
|---|---|
| Series Name | Standard format |
| Product Or Component Type | Limit switch |
| Device Short Name | XCKJ |
| Body Type | Fixed |
| Head Type | Rotary head |
| Material | Metal |
| Body Material | Zamak |
| Head Material | Zamak |
| Fixing Mode | By the body |
| Movement Of Operating Head | Rotary |
| Type Of Operator | Spring return roller lever thermoplastic variable length |
| Type Of Approach | Lateral approach, 1 or 2 programmable direction |
| Cable Entry | 1 entry tapped for Pg 13.5 cable gland 0.35…0.47 in (9…12 mm) |
| Number Of Poles | 2 |
| Contacts Type And Composition | 1 NC + 1 NO |
| Contact Operation | Slow-break, break before make |
| Switch Actuation | By 30° cam |
| Electrical Connection | Screw-clamp terminals 1 x 0.5...2 x 2.5 mm² |
| Contacts Insulation Form | Zb |
| Number Of Steps | 1 |
| Positive Opening | Without |
| Minimum Torque For Tripping | 2.21 lbf.in (0.25 N.m) |
| Minimum Actuation Speed | 6 m/min |
| Maximum Actuation Speed | 4.92 ft/s (1.5 m/s) |
| Ie Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
| Ithe Cnvtl Enclosed Therm Crrt | 10 A |
| Ui Rated Insulation Voltage | 300 VUL 508 500 V 3)IEC 60947-1 300 VCSA C22.2 No 14 |
| Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 |
| Uimp Rated Imp Wstd Voltage | 6 kV IEC 60664 6 kV IEC 60947-1 |
| Short-Circuit Protection | 10 A cartridge fuse gG |
| Electrical Durability | 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
| Mechanical Durability | 30000000 cycles |
| Width | 1.57 in (40 mm) |
| Height | 3.03 in (77 mm) |
| Depth | 1.73 in (44 mm) |
| Product Weight | 1.07 lb(US) (0.485 kg) |
| Terminals Description ISO n°1 | (13-14)NO (21-22)NC |
| Shock Resistance | 50 gn 11 ms IEC 60068-2-27 |
| Vibration Resistance | 25 gn 10…500 Hz)IEC 60068-2-6 |
| IP Degree Of Protection | IP66 IEC 60529 |
| IK Degree Of Protection | IK07 EN 50102 |
| Overvoltage Category | Class I IEC 61140 Class I NF C 20-030 |
| Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Protective Treatment | TC |
| Product Certifications | CCC UL CSA |
| Standards | IEC 60204-1 EN 60204-1 CSA C22.2 No 14 UL 508 CENELEC EN 50041 IEC 60947-5-1 EN 60947-5-1 |
| Category | 22411-LIMIT SWITCHES,IEC,XCKJ |
| Discount Schedule | T |