Specifications
Part Number XCKD2111M12
Country of Origin FR
UPC 389110197792
UPC11 38911019779
EAN 3389110197792
Availability N
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.18 inch
Height 2.56 inch
Width 1.22 inch
Weight 0.42 pound
Characteristics
Range Of Product OsiSense XC
Series Name Standard format
Product Or Component Type Limit switch
Device Short Name XCKD
Sensor Design Compact
Body Type Fixed
Head Type Plunger head
Material Metal
Body Material Zamak
Head Material Zamak
Fixing Mode By the body
Movement Of Operating Head Linear
Type Of Operator Spring return roller plunger metal with nitrile boot
Type Of Approach Vertical approach, 1 direction
Number Of Poles 2
Contacts Type And Composition 1 NC + 1 NO
Contact Operation Snap action
Switch Actuation On end
Electrical Connection Male connector M12, 5 pins
Contacts Insulation Form Zb
Positive Opening With
Positive Opening Min Force 45 N
Minimum Force For Tripping 15 N
Minimum Actuation Speed 0.01 m/min
Maximum Actuation Speed 1.64 ft/s (0.5 m/s)
Repeat Accuracy 0.1 mm on the tripping points with 1 million operating cycles
Ie Rated Operational Current 3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A 0.27 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 4 A
Ui Rated Insulation Voltage 60 V 3)IEC 60947-1
Resistance Across Terminals 25 MOhm IEC 60255-7 category 3
Uimp Rated Imp Wstd Voltage 0.8 kV IEC 60664 0.8 kV IEC 60947-1
Short-Circuit Protection 4 A cartridge fuse gG
Electrical Durability 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical Durability 15000000 cycles
Width 1.22 in (31 mm)
Height 2.56 in (65 mm)
Depth 1.18 in (30 mm)
Product Weight 0.42 lb(US) (0.19 kg)
Terminals Description ISO n°1 (13-14)NO (21-22)NC
Shock Resistance 50 gn 11 ms IEC 60068-2-27
Vibration Resistance 25 gn 10…500 Hz)IEC 60068-2-6
IK Degree Of Protection IK06 EN 50102
Electrical Shock Protect Class Class I IEC 61140 Class I NF C 20-030
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Protective Treatment TC
Product Certifications UL CCC CSA
Standards CSA C22.2 No 14 IEC 60204-1 EN 60947-5-1 IEC 60947-5-1 EN 60204-1 UL 508
Category 22418 - LIMIT SWITCH,IEC,XCKP&XCKT
Discount Schedule T
Documents