Part Number | XC1AC126H2 |
---|---|
Country of Origin | FR |
UPC | 389118124004 |
UPC11 | 38911812400 |
EAN | 3389118124004 |
Availability | N |
Lead Time | 20 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509055 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
Discount Schedule | T |
Return Indicator | No |
Depth | 1.73 inch |
Height | 6.18 inch |
Width | 3.03 inch |
Weight | 1.92 pound |
Range Of Product | OsiSense XC |
---|---|
Series Name | Special format |
Product Or Component Type | Limit switch |
Product Specific Application | Materials handling |
Device Short Name | XC1AC |
Body Type | Fixed |
Head Type | Plunger head |
Material | Metal |
Fixing Mode | By the body |
Movement Of Operating Head | Linear |
Type Of Operator | Spring return roller lever metal - |
Switch Actuation | By 30° cam |
Type Of Approach | Lateral approach, 2 directions |
Electrical Connection | Screw-clamp terminals 1 x 0.5...1 x 2.5 mm² |
Number Of Poles | 2 |
Contacts Type And Composition | 1 NC + 1 NO |
Contact Operation | Slow-break, break before make |
Number Of Steps | 1 |
Positive Opening | Without |
Minimum Force For Tripping | 23 N |
Contacts Insulation Form | Zb |
Maximum Actuation Speed | 3.28 ft/s (1 m/s) from left 1.64 ft/s (0.5 m/s) from right |
Ithe Cnvtl Enclosed Therm Crrt | 10 A |
Ui Rated Insulation Voltage | 500 V ACIEC 60947-5-1 500 V ACNF C 20-040 600 V DCIEC 60947-5-1 600 V DCNF C 20-040 600 V ACCSA C22.2 No 14 600 V DCCSA C22.2 No 14 |
Resistance Across Terminals | 8 mOhm |
Short-Circuit Protection | 10 A cartridge fuse gG |
Electrical Durability | 1000000 cycles, AC-15 50/60 Hz, inductive, 110 V, 900 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 1000000 cycles, AC-15 50/60 Hz, inductive, 230 V, 1900 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 1000000 cycles, AC-15 50/60 Hz, inductive, 48 V, 450 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 1000000 cycles, DC-13, inductive, 110 V, 100 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 1000000 cycles, DC-13, inductive, 230 V, 95 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 1000000 cycles, DC-13, inductive, 48 V, 100 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 3000000 cycles, AC-15 50/60 Hz, inductive, 110 V, 350 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 3000000 cycles, AC-15 50/60 Hz, inductive, 230 V, 430 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 3000000 cycles, AC-15 50/60 Hz, inductive, 48 V, 170 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 3000000 cycles, DC-13, inductive, 110 V, 40 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 3000000 cycles, DC-13, inductive, 230 V, 33 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 3000000 cycles, DC-13, inductive, 48 V, 35 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C |
Mechanical Durability | 10000000 cycles |
Width | 3.03 in (77 mm) |
Height | 6.18 in (157 mm) |
Depth | 1.73 in (44 mm) |
Product Weight | 1.92 lb(US) (0.87 kg) |
Terminals Description ISO n°1 | (13-14)NO (11-12)NC |
Shock Resistance | 95 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 9 gn 10…500 Hz)IEC 60068-2-6 |
IP Degree Of Protection | IP65 IEC 60529 IP65 NF C 20-010 |
Electrical Shock Protect Class | Class I IEC 61140 Class I NF C 20-030 |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Protective Treatment | TC |
Operating Position | Any position |
Product Certifications | CSA |
Standards | CSA C22.2 No 14 IEC 60947-5-1 EN 60947-5-1 IEC 60337-1 VDE 0660-200 |
Category | 22449 - LIMIT SWITCHES,ACCESSORIES |
Discount Schedule | T |
GTIN | 03389118124004 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | FR |
EU RoHs Directive | Not applicable, out of EU RoHS legal scope |
Warranty | 18 months |