Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Limit switch for safety application – XCS-TE – operating key – 1 NC + 1 NO
XCSTE5542
Limit switch for safety application – XCS-TE – operating key – 1 NC + 1 NO
Specifications
Part Number XCSTE5542
Country of Origin FR
UPC 389110825541
UPC11 38911082554
EAN 3389110825541
Availability F
Lead Time 20
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.30 inch
Height 3.70 inch
Width 4.33 inch
Weight 0.79 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Safety switch
Component Name XCSTE
Design Rectangular
Material Plastic
Head Type Key operated turret head
Contacts Type And Composition 1 NC + 1 NO
Contact Operation Slow-break, break before make
Solenoid Contacts Type Compo 1 NC slow-break)
Cable Entry 1 entry tapped Pg 11
Electromagnet Interlocking Locking on energisation and unlocking on de-energisation of solenoid
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage 230 V - 20...10 %
Cable Outer Diameter 0.28…0.39 in (7…10 mm)
Electrical Connection Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Number Of Poles 2
Locking Options Description With interlocking, locking by solenoid
Insulation Double insulated
Positive Opening With NC contact
Supply Voltage Type AC/DC
Supply Frequency 50/60 Hz
Load Factor 1
Power Consumption In Va 10 VA
Mechanical Durability 1000000 cycles
Positive Opening Min Force 15 N
Minimum Actuation Speed 0.03 ft/s (0.01 m/s)
Maximum Actuation Speed 1.64 ft/s (0.5 m/s)
Ie Rated Operational Current 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Ithe Cnvtl Enclosed Therm Crrt 6 A
Ui Rated Insulation Voltage 300 VUL 508 500 VEN/IEC 60947-1 300 VCSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-5-1
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Actutr Forcible Withdrawal Rtc 500 N
Operating Rate 10 cyc/mn for maximum durability
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body Material PA (polyamide)
Head Material PA (polyamide)
Depth 1.30 in (33 mm)
Height 3.70 in (94 mm)
Width 4.33 in (110 mm)
Product Weight 0.79 lb(US) (0.36 kg)
Standards EN/IEC 60204-1 UL 508 EN/ISO 12100 EN 1088/ISO 14119 EN/IEC 60947-5-1 CSA C22.2 No 14
Product Certifications CSA UL
Protective Treatment TC
Ambient Air Temp For Op -13…140 °F (-25…60 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Vibration Resistance 5 gn 10…500 Hz)IEC 60068-2-6
Shock Resistance 10 gn 11 ms IEC 60068-2-27
Electrical Shock Protect Class Class II EN/IEC 61140
IP Degree Of Protection IP67 EN/IEC 60529 and EN/IEC 60947-5-1
Documents