Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LIMIT SWITCH – 240V AC – 10AM – XCKJ + OPTIONS
XCKJ110971DSAH
LIMIT SWITCH – 240V AC – 10AM – XCKJ + OPTIONS
Specifications
Part Number XCKJ110971DSAH
Country of Origin FR
UPC 785901952916
UPC11 78590195291
EAN 3389119061865
Availability N
Lead Time 20
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.42 inch
Height 3.31 inch
Width 1.69 inch
Weight 1.07 pound
Characteristics
Range Of Product OsiSense XC
Series Name Standard format
Product Or Component Type Limit switch
Device Short Name XCKJ
Sensor Design Form D CENELEC EN 50041
Body Type Plug-in body
Head Type Rotary head
Material Metal
Body Material Zamak
Head Material Zamak
Fixing Mode By the body
Movement Of Operating Head Rotary
Type Of Operator Spring return round rod lever thermoplastic round rod 6 mm, L = 200 mm
Type Of Approach Lateral approach, 1 or 2 programmable direction
Cable Entry 1 entry tapped for 1/2" NPT cable gland
Number Of Poles 1
Contacts Type And Composition 1 C/O
Contact Operation Snap action
Switch Actuation By any moving part
Electrical Connection Screw-clamp terminals 1 x 0.75...2 x 1.5 mm²
Contacts Insulation Form Zb
Number Of Steps 1
Positive Opening Without
Minimum Torque For Tripping 2.21 lbf.in (0.25 N.m)
Maximum Actuation Speed 4.92 ft/s (1.5 m/s)
Ie Rated Operational Current 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 10 A
Ui Rated Insulation Voltage 300 VUL 508 500 V 3)IEC 60947-1 300 VCSA C22.2 No 14
Resistance Across Terminals 25 MOhm IEC 60255-7 category 3
Uimp Rated Imp Wstd Voltage 6 kV IEC 60664 6 kV IEC 60947-1
Short-Circuit Protection 10 A cartridge fuse gG
Electrical Durability 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical Durability 30000000 cycles
Width 1.69 in (43 mm)
Height 3.31 in (84 mm)
Depth 1.42 in (36 mm)
Product Weight 1.07 lb(US) (0.485 kg)
Terminals Description ISO n°1 (11-12)NC (13-14)NO
Shock Resistance 50 gn 11 ms IEC 60068-2-27
Vibration Resistance 25 gn 10…500 Hz)IEC 60068-2-6
IP Degree Of Protection IP66 IEC 60529
IK Degree Of Protection IK07 EN 50102
Overvoltage Category Class I IEC 61140 Class I NF C 20-030
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Protective Treatment TC
Product Certifications UL CCC CSA
Standards IEC 60204-1 CSA C22.2 No 14 IEC 60947-5-1 CENELEC EN 50041 EN 60204-1 EN 60947-5-1 UL 508
Category 22411 - LIMIT SWITCHES,IEC,XCKJ
Discount Schedule T
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews