Part Number | S8650B4C0H6C7B0A |
---|---|
Availability | N |
UNSPSC | 39121103 |
ECCN | EAR99 |
HTs Code | 9030840000 |
Prop 65 | This product can expose you to chemicals including: Dichloromethane (Methylene chloride) and Bisphenol A (BPA) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
Discount Schedule | PM1S |
Return Indicator | No |
Depth | 8.98 inch |
Height | 11.22 inch |
Width | 6.42 inch |
Weight | 15.43 pound |
Range | PowerLogic |
---|---|
Product Name | PowerLogic ION8650 |
Device Short Name | ION8650B |
Product Or Component Type | Energy and power quality meter |
Power Quality Analysis | harmonic distortion programmablity (logic and math functions) voltage sag and swell detection up to the 63rd harmonic IEC 61000-4-15 flicker transient capture EN 50160 compliance report IEC 61000-4-30 class S power quality measurement magnitude harmonic up to the 40th EN 50160 ed. 4 power quality monitoring |
Device Application | Load curtailment Demand and power factor control Equipment monitoring and control Instrument transformer correction Tariff metering Energy pulsing and totalisation Co-generation and IPP monitoring |
Type Of Measurement | Power factor total Power factor per phase Apparent power total Apparent power per phase Active power total Active power per phase Reactive power total Reactive power per phase Current Voltage Frequency |
Supply Voltage | 120...277 V AC 47...63 Hz 120...480 V AC 47...63 Hz 65...120 V AC 47...63 Hz 80...160 V DC |
Network Frequency | 60 Hz |
Outlet Standard | American |
In Rated Current | 2 A 5 A 1 A |
Poles Description | 3P + N 3P 1P + N |
Power Consumption In Va | 24 VA |
Power Consumption In Va | 33 VA |
Display Type | FSTN transflective LCD |
Form Designation | 36S 2 1/2-element 4 9 3-element 4 35 2-element 3 29 2 1/2-element 4 |
Sampling Rate | 1024 samples/cycle |
Measurement Current | 0.001…24 A |
Input Type | current 0.01...20 A 0.05 Ohm) |
Measurement Voltage | 57…277 V AC phase to neutral 100…480 V AC phase to phase |
Number Of Inputs | 3 digital 0.001...100 mA 30 V DC |
Measurement Accuracy | Current 0.1 % Voltage 0.1 % Power 0.1 % Power factor 0.1 % Frequency 0.001 Hz Energy 0.1 % |
Accuracy Class | Class 0.2S energy IEC 62053-22 Class 0.2S energy IEC 62053-23 Class 0.2 energy ANSI C12.20 |
Number Of Outputs | 2 pulse 4 form C relay output |
Communication Port Protocol | TCP/IP 10/100 Mbit/s DNP3 300...115200 bauds ION 300...115200 bauds DLMS 300...115200 bauds Modbus 57600 bauds Ansi C12.18 <= 19200 bauds DNP3 10/100 Mbit/s ION 10/100 Mbit/s IEC 61850 ed. 2 10/100 Mbit/s TCP/IP 300...57600 bauds Modbus RTU, master/slave 300...115200 bauds Modbus TCP, master/slave 10/100 Mbit/s EtherGate ModemGate |
Communication Port Support | RJ11 modem RJ45 Ethernet SUB-D 9 RS485/RS232 infrared Terminal block RS485 |
Time Synchronisation Protocol | IRIG-B GPS: Truetime/Datum |
Data Recording | GPS synchronisation Time stamping Alarms Harmonics logs Historical logs Sag and swell logs Event logs Revenue logs Data logs |
Transmission Rate | 10/100 Mbit/s 57600 bauds 300...115200 bauds <= 19200 bauds 300...57600 bauds |
Memory Capacity | 64 MB |
Web Services | Web server Port addressing user designed Alarm notification by e-mail Robust security logs |
Ethernet Service | SNMP-Traps and SYSLOG Enable/disable serial ports Enable/disable Ethernet protocols |
Tamperproof Of Settings | Protected by access code |
Provided Equipment | Break out panel |
Compatibility Code | ION8650B |
Electromagnetic Compatibility | Electrostatic discharge immunity test IEC 61000-4-2 Susceptibility to electromagnetic fields IEC 61000-4-3 Electrical fast transient/burst immunity test IEC 61000-4-4 1.2/50 µs shock waves immunity test IEC 61000-4-5 Conducted and radiated emissionsB CISPR 22 Conducted RF disturbances IEC 61000-4-6 Immunity to impulse waves IEC 61000-4-12 |
Mounting Mode | Flush-mounted |
Enclosure Type | FT21 switchboard |
Type Of Installation | Indoor installation |
Overvoltage Category | III |
IP Degree Of Protection | Back IP30 Front face IP50 |
Relative Humidity | 5…95 % |
Pollution Degree | 2 |
Ambient Air Temp For Op | -40…185 °F (-40…85 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Operating Altitude | 0...9842.52 ft (0...3000 m) |
Standards | ANSI C12.1 IEC 62052-11 |
Width | 6.42 in (163 mm) |
Depth | 8.98 in (228 mm) |
Height | 11.22 in (285 mm) |