Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
ION8650 meter 64MB, FT21 panel, 120VAC/160VDC 60Hz, Full comm 3I+4O
S8650B4C0H6C7B0A
ION8650 meter 64MB, FT21 panel, 120VAC/160VDC 60Hz, Full comm 3I+4O
Specifications
Part Number S8650B4C0H6C7B0A
Availability N
UNSPSC 39121103
ECCN EAR99
HTs Code 9030840000
Prop 65 This product can expose you to chemicals including: Dichloromethane (Methylene chloride) and Bisphenol A (BPA) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
Discount Schedule PM1S
Return Indicator No
Depth 8.98 inch
Height 11.22 inch
Width 6.42 inch
Weight 15.43 pound
Characteristics
Range PowerLogic
Product Name PowerLogic ION8650
Device Short Name ION8650B
Product Or Component Type Energy and power quality meter
Power Quality Analysis harmonic distortion programmablity (logic and math functions) voltage sag and swell detection up to the 63rd harmonic IEC 61000-4-15 flicker transient capture EN 50160 compliance report IEC 61000-4-30 class S power quality measurement magnitude harmonic up to the 40th EN 50160 ed. 4 power quality monitoring
Device Application Load curtailment Demand and power factor control Equipment monitoring and control Instrument transformer correction Tariff metering Energy pulsing and totalisation Co-generation and IPP monitoring
Type Of Measurement Power factor total Power factor per phase Apparent power total Apparent power per phase Active power total Active power per phase Reactive power total Reactive power per phase Current Voltage Frequency
Supply Voltage 120...277 V AC 47...63 Hz 120...480 V AC 47...63 Hz 65...120 V AC 47...63 Hz 80...160 V DC
Network Frequency 60 Hz
Outlet Standard American
In Rated Current 2 A 5 A 1 A
Poles Description 3P + N 3P 1P + N
Power Consumption In Va 24 VA
Power Consumption In Va 33 VA
Display Type FSTN transflective LCD
Form Designation 36S 2 1/2-element 4 9 3-element 4 35 2-element 3 29 2 1/2-element 4
Sampling Rate 1024 samples/cycle
Measurement Current 0.001…24 A
Input Type current 0.01...20 A 0.05 Ohm)
Measurement Voltage 57…277 V AC phase to neutral 100…480 V AC phase to phase
Number Of Inputs 3 digital 0.001...100 mA 30 V DC
Measurement Accuracy Current 0.1 % Voltage 0.1 % Power 0.1 % Power factor 0.1 % Frequency 0.001 Hz Energy 0.1 %
Accuracy Class Class 0.2S energy IEC 62053-22 Class 0.2S energy IEC 62053-23 Class 0.2 energy ANSI C12.20
Number Of Outputs 2 pulse 4 form C relay output
Communication Port Protocol TCP/IP 10/100 Mbit/s DNP3 300...115200 bauds ION 300...115200 bauds DLMS 300...115200 bauds Modbus 57600 bauds Ansi C12.18 <= 19200 bauds DNP3 10/100 Mbit/s ION 10/100 Mbit/s IEC 61850 ed. 2 10/100 Mbit/s TCP/IP 300...57600 bauds Modbus RTU, master/slave 300...115200 bauds Modbus TCP, master/slave 10/100 Mbit/s EtherGate ModemGate
Communication Port Support RJ11 modem RJ45 Ethernet SUB-D 9 RS485/RS232 infrared Terminal block RS485
Time Synchronisation Protocol IRIG-B GPS: Truetime/Datum
Data Recording GPS synchronisation Time stamping Alarms Harmonics logs Historical logs Sag and swell logs Event logs Revenue logs Data logs
Transmission Rate 10/100 Mbit/s 57600 bauds 300...115200 bauds <= 19200 bauds 300...57600 bauds
Memory Capacity 64 MB
Web Services Web server Port addressing user designed Alarm notification by e-mail Robust security logs
Ethernet Service SNMP-Traps and SYSLOG Enable/disable serial ports Enable/disable Ethernet protocols
Tamperproof Of Settings Protected by access code
Provided Equipment Break out panel
Compatibility Code ION8650B
Electromagnetic Compatibility Electrostatic discharge immunity test IEC 61000-4-2 Susceptibility to electromagnetic fields IEC 61000-4-3 Electrical fast transient/burst immunity test IEC 61000-4-4 1.2/50 µs shock waves immunity test IEC 61000-4-5 Conducted and radiated emissionsB CISPR 22 Conducted RF disturbances IEC 61000-4-6 Immunity to impulse waves IEC 61000-4-12
Mounting Mode Flush-mounted
Enclosure Type FT21 switchboard
Type Of Installation Indoor installation
Overvoltage Category III
IP Degree Of Protection Back IP30 Front face IP50
Relative Humidity 5…95 %
Pollution Degree 2
Ambient Air Temp For Op -40…185 °F (-40…85 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
Operating Altitude 0...9842.52 ft (0...3000 m)
Standards ANSI C12.1 IEC 62052-11
Width 6.42 in (163 mm)
Depth 8.98 in (228 mm)
Height 11.22 in (285 mm)