Part Number | M8650C0C0J6A0A0A |
---|---|
UNSPSC | 39121603 |
Depth | 9.33 inch |
Height | 7.01 inch |
Width | 7.01 inch |
Weight | 15.43 pound |
Range | PowerLogic |
---|---|
Device Short Name | ION8650C |
Product Or Component Type | Energy and power quality meter |
Power Quality Analysis | up to the 31st harmonic harmonic distortion voltage sag and swell detection programmablity (logic and math functions) |
Device Application | Co-generation and IPP monitoring Demand and power factor control Equipment monitoring and control Load curtailment Energy pulsing and totalisation Tariff metering Instrument transformer correction |
Type Of Measurement | Current Voltage Frequency Apparent power total Power factor total Apparent power per phase Power factor per phase Active power total Active power per phase Reactive power total Reactive power per phase |
Supply Voltage | 120...277 V AC 47...63 Hz 160...277 V AC 47...63 Hz 200...300 V DC |
Network Frequency | 60 Hz |
Outlet Standard | American |
In Rated Current | 2 A 5 A 1 A |
Type Of Network | 1P + N 3P 3P + N |
Power Consumption In Va | 24 VA |
Power Consumption In Va | 33 VA |
Display Type | FSTN transflective LCD |
Form Designation | 9S 3-element 4 36S 2 1/2-element 4 29S 2 1/2-element 4 |
Sampling Rate | 1024 samples/cycle |
Measurement Current | 0.001…24 A |
Input Type | current 0.01...20 A 0.05 Ohm) |
Measurement Voltage | 57…277 V AC phase to neutral 100…480 V AC phase to phase |
Measurement Accuracy | Current 0.1 % Voltage 0.1 % Power 0.1 % Power factor 0.1 % Frequency 0.001 Hz Energy 0.1 % |
Accuracy Class | Class 0.2S energy IEC 62053-23 Class 0.2 energy ANSI C12.20 Class 0.2S energy IEC 62053-22 |
Number Of Outputs | 2 pulse |
Communication Port Protocol | DNP3 300...115200 bauds ION 300...115200 bauds Ansi C12.18 <= 19200 bauds DLMS 300...115200 bauds Modbus 57600 bauds Modbus RTU, slave 300...115200 bauds |
Communication Port Support | SUB-D 9 RS485/RS232 Terminal block RS485 infrared |
Time Synchronisation Protocol | IRIG-B GPS: Truetime/Datum |
Data Recording | Time stamping Alarms Data logs Sag and swell logs Revenue logs Event logs GPS synchronisation Harmonics logs Historical logs |
Transmission Rate | 300...115200 bauds <= 19200 bauds 57600 bauds |
Memory Capacity | 32 MB |
Web Services | Robust security logs Port addressing user designed Web server Alarm notification by e-mail |
Ethernet Service | Enable/disable serial ports SNMP-Traps and SYSLOG Enable/disable Ethernet protocols |
Tamperproof Of Settings | Protected by access code |
Compatibility Code | ION8650C |
Electromagnetic Compatibility | Electrostatic discharge immunity test IEC 61000-4-2 Conducted RF disturbances IEC 61000-4-6 Immunity to impulse waves IEC 61000-4-12 Electrical fast transient/burst immunity test IEC 61000-4-4 Susceptibility to electromagnetic fields IEC 61000-4-3 1.2/50 µs shock waves immunity test IEC 61000-4-5 Conducted and radiated emissionsB CISPR 22 |
Mounting Mode | Socket-mounted |
Mounting Support | Enclosure door |
Type Of Installation | Indoor installation |
Overvoltage Category | III |
IP Degree Of Protection | Front face IP65 Back IP51 |
Relative Humidity | 5…95 % |
Pollution Degree | 2 |
Ambient Air Temp For Op | -40…185 °F (-40…85 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Operating Altitude | 0...9842.52 ft (0...3000 m) |
Standards | ANSI C12.1 IEC 62052-11 |
Width | 7.01 in (178 mm) |
Depth | 9.33 in (237 mm) |
Height | 7.01 in (178 mm) |
Product Weight | 15.43 lb(US) (7 kg) |
Warranty | 18 months |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211