Specifications
Part Number GVSUPS20KB2GS
Depth 33.35 inch
Height 58.46 inch
Width 13.11 inch
Weight 540.13 pound
Characteristics
Presentation Highly efficient, easy-to-deploy 20kW, 480V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 1 smart modular battery string, expandable to 2 strings for extended runtime. Runtime charts available in the Documents tab.
Lead Time Usually Ships within 2 Weeks
Provided Equipment Dust filter Installation guide Integrated network management Power modules ship installed Start-Up Service Top and bottom cable entry
Bypass Voltage Tolerance +/- 10 %
Surface Finish Gloss level 85%
Colour White RAL 9003)
Depth 33.35 in (84.7 cm)
Height 58.46 in (148.5 cm)
Product Weight 540.13 lb(US) (245 kg)
Width 13.11 in (33.3 cm)
Network Frequency 40 - 70 Hz
Number Of Input Connectors 1 Hard Wire 4-wire (3PH + G)
Input Voltage Limits 408...552 V 480 V
Maximum Input Current 30 A
Max Short Time Withstd Current 65 kA
Input Harmonic Distortion Less than 3% for full load
Input Voltage 3 phase
Rated Power In W 20000 W
Max Configurable Power In W 20000 W
Harmonic Distortion Less than 3%
Output Frequency 50 Hz sync to mains 60 Hz sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal not synced 60 Hz +/- 0.1 % for 60 Hz nominal not synced
Crest Factor 2.5
Ups Type Double Conversion Online
Wave Type Sine wave
Output Connector Type Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1
Output Voltage Tolerance +/-1% after 50ms
Output Harmonic Distortion < 1% linear load and < 3% non-linear load
Output Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Bypass Type Built-in Static Bypass
Output Voltage 480 V 3 phase
Product Certifications ENERGY STAR V2.0 (USA) UL 1778 5th edition
Standards CSA C22.2 No 107.3 FCC Part 15 class A IEC 62040-3 IEC 60721-4-2 Level 2M2 UL 1778 5th edition
Ambient Air Temp For Op 32…104 °F (0…40 °C)
Relative Humidity 0…95 % non-condensing
Operating Altitude 0...3281 ft
Ambient Air Temp For Storage 5…104 °F (-15…40 °C)
Storage Altitude 0…10000 ft (0.00…3048.00 m)
Acoustic Level 65 dBA
Heat Dissipation 2225 Btu/h
IP Degree Of Protection IP20
Battery Type VRLA
Battery Voltage 480V
Discharge Battery Voltage 384 V DC
Max Current Discharge 54 A
Free Slots 1
Control Panel Touch Screen LCD User Interface
Alarm Audible and visible alarms prioritized by severity