| Part Number | GVSUPS10KFS |
|---|---|
| Depth | 33.35 inch |
| Height | 58.46 inch |
| Width | 20.51 inch |
| Weight | 462.97 pound |
| Presentation | Highly efficient, easy-to-deploy 10kW, 208V 3-phase uninterruptible power supply (UPS) that brings best-in-class power protection to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Compact design, high-density technology and modular architecture keep total cost of ownership low and operational efficiency at the highest levels. Galaxy VS reduces your energy losses by up to 66% with the patented ECOnversion mode – reaching up to 99% efficiency levels and delivering more energy savings than even our industry-leading 97% efficiency in normal operating mode. The UPS is EcoStruxure-ready to give you peace of mind with cloud-based remote monitoring and management via your smartphone. Includes 5x8 start-up service. For battery runtime details, see the runtime charts published under the Documents tab. |
|---|---|
| Lead Time | Usually Ships within 2 Weeks |
| Provided Equipment | Dust filter Installation guide Integrated network management Power modules ship installed Start-Up Service Top and bottom cable entry |
| Bypass Voltage Tolerance | +/- 10 % |
| Max Bypass Input Current | 35 A |
| Surface Finish | Gloss level 85% |
| Colour | White RAL 9003) |
| Depth | 33.35 in (84.7 cm) |
| Height | 58.46 in (148.5 cm) |
| Product Weight | 462.97 lb(US) (210 kg) |
| Width | 20.51 in (52.1 cm) |
| Network Frequency | 40 - 70 Hz |
| Number Of Input Connectors | 1 Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) |
| Input Voltage Limits | 177...239 V 208 V |
| Inputvolt_Other | 200 V 220 V |
| Maximum Input Current | 37 A |
| Input Harmonic Distortion | Less than 3% for full load |
| Input Voltage | 3 phase |
| Rated Power In W | 10000 W |
| Max Configurable Power In W | 10000 W |
| Harmonic Distortion | Less than 3% |
| Output Frequency | 50 Hz sync to mains 60 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced 50 Hz +/- 0.1 % for 50 Hz nominal not synced |
| Outputvolt_Other | 200 V 220 V |
| Crest Factor | 2.5 |
| Ups Type | Double Conversion Online |
| Wave Type | Sine wave |
| Output Connector Type | Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1 |
| Output Voltage Tolerance | +/-1% after 50ms |
| Output Harmonic Distortion | < 1% linear load and < 3% non-linear load |
| Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
| Bypass Type | Built-in Static Bypass |
| Output Voltage | 208 V 3 phase |
| Standards | CSA C22.2 No 107.3 FCC Part 15 class A IEC 62040-3 IEC 60721-4-2 Level 2M2 UL 1778 5th edition |
| Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
| Relative Humidity | 0…95 % non-condensing |
| Operating Altitude | 0...3281 ft |
| Ambient Air Temp For Storage | -13…131 °F (-25…55 °C) |
| Storage Altitude | 0…50000 ft (0.00…15240.00 m) |
| Acoustic Level | 65 dBA |
| Heat Dissipation | 1891 Btu/h |
| IP Degree Of Protection | IP21 |
| Battery Type | External battery system |
| Battery Voltage | 384-480VDC |
| Discharge Battery Voltage | 307 V DC |
| Short-Circuit Current | 65 kA |
| Max Current Discharge | 34 A |
| Free Slots | 1 |