Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Galaxy VS UPS 10kW 208V, 1 internal 7Ah smart modular battery string, expandable to 2, Start-up 5×8
GVSUPS10KB2FS
Galaxy VS UPS 10kW 208V, 1 internal 7Ah smart modular battery string, expandable to 2, Start-up 5×8
Specifications
Part Number GVSUPS10KB2FS
Depth 33.35 inch
Height 58.46 inch
Width 13.11 inch
Weight 540.13 pound
Characteristics
Presentation Highly efficient, easy-to-deploy 10kW, 208V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 1 smart modular battery string, expandable to 2 strings for extended runtime. Runtime charts available in the Documents tab.
Lead Time Usually Ships within 2 Weeks
Provided Equipment Battery modules ship installed Dust filter EcoStruxure IT ready (UPS) Installation guide Integrated network management Power modules ship installed Start-Up Service
Bypass Voltage Tolerance +/- 10 %
Surface Finish Gloss level 85%
Colour White RAL 9003)
Depth 33.35 in (84.7 cm)
Height 58.46 in (148.5 cm)
Product Weight 540.13 lb(US) (245 kg)
Width 13.11 in (33.3 cm)
Network Frequency 40 - 70 Hz
Input Voltage Limits 177...239 V 208 V
Inputvolt_Other 200 V 220 V
Maximum Input Current 36 A
Max Short Time Withstd Current 65 kA
Input Harmonic Distortion Less than 3% for full load
Input Voltage 3 phase
Rated Power In W 10000 W
Max Configurable Power In W 10000 W
Output Frequency 50 Hz sync to mains 60 Hz sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal not synced 60 Hz +/- 0.1 % for 60 Hz nominal not synced
Outputvolt_Other 200 V 220 V
Crest Factor 2.5
Ups Type Double Conversion Online
Wave Type Sine wave
Output Voltage Tolerance +/-1% after 50ms
Output Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Bypass Type Built-in Static Bypass
Output Voltage 208 V 3 phase
Standards CSA C22.2 No 107.3 FCC Part 15 class A IEC 62040-3 IEC 60721-4-2 Level 2M2 UL 1778 5th edition
Ambient Air Temp For Op 32…104 °F (0…40 °C)
Relative Humidity 0…95 % non-condensing
Operating Altitude 0...3281 ft
Ambient Air Temp For Storage 5…104 °F (-15…40 °C)
Storage Altitude 0…10000 ft (0.00…3048.00 m)
Acoustic Level 65 dBA
Heat Dissipation 2231 Btu/h
IP Degree Of Protection IP20
Battery Type VRLA
Battery Voltage 480V
Discharge Battery Voltage 384 V DC
Max Current Discharge 27 A
Free Slots 1
Control Panel Touch Screen LCD User Interface
Alarm Audible and visible alarms prioritized by severity
EU RoHs Directive Under investigation
Warranty 1 year on-site repair or replace with factory authorized Start-Up
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews