Part Number | GVMS180KGF65S |
---|---|
UPC | 731304326557 |
UPC11 | 73130432655 |
EAN | 0731304326557 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
Depth | 33.62 inch |
Height | 77.56 inch |
Width | 70.94 inch |
Weight | 4134.99 pound |
Presentation | A highly compact, energy efficient 3-phase UPS with an integrated 480-208 volt transformer for data center, facility and industrial applications. |
---|---|
Lead Time | Usually Ships within 2 Weeks |
Provided Equipment | Installation guide Start-Up Service |
Bypass Voltage Tolerance | +/-10% settable from +/-4/6/8 and 10% |
Max Bypass Input Current | 217 A |
Bypass Current Protection | 400 A |
Colour | White |
Depth | 33.62 in (85.4 cm) |
Height | 77.56 in (197 cm) |
Product Weight | 4134.99 lb(US) (1875.6 kg) |
Width | 70.94 in (180.2 cm) |
Network Frequency | 40 - 70 Hz |
Number Of Input Connectors | 1 Hard Wire 3-wire (3PH + G) |
Input Voltage Limits | 360...576 V adjustable 480 V 360...576 V 480 V |
Maximum Input Current | 278 A |
Switching Current Capacity | 400 A |
Max Short Time Withstd Current | 65 kA |
Input Harmonic Distortion | Less than 3% for full load |
Input Protection Type | 3-pole breaker |
Input Voltage | 3 phase |
Rated Power In W | 162000 W |
Max Configurable Power In W | 162000 W |
Harmonic Distortion | Less than 2% |
Output Frequency | 50/60 Hz +/- 1 Hz sync to mains 50/60 Hz +/- 1 Hz not synced |
Crest Factor | Unlimited |
Ups Type | Double Conversion Online |
Wave Type | Sine wave |
Output Connector Type | Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1 |
Output Voltage Tolerance | +/- 1% static and +/- 3% at 100% load step |
Output Harmonic Distortion | < 2% linear load and < 3% non-linear load |
Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
Req Output Current Protection | 500 A |
Neutral Output Current | 195 A |
Bypass Type | Built-in Static Bypass |
Output Voltage | 208 V 3 phase |
Product Certifications | CUL Listed FCC part 15 class A UL 1778 |
Standards | EN/IEC 62040-3 IBC 2012 and CBC2013 to Sds=2.02g OSHPD |
Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
Relative Humidity | 0…95 % |
Operating Altitude | 0...3333 ft |
Ambient Air Temp For Storage | 5…104 °F (-15…40 °C) |
Storage Altitude | 0…49212 ft (0.00…14999.82 m) |
Acoustic Level | 65 dBA |
Heat Dissipation | 12284 Btu/h |
IP Degree Of Protection | IP20 |
Battery Type | External battery system |
Battery Voltage | 480V |